100
A
A
1900
20
max.
500
A
150
100
100
150
TH2-30Ni2
TH3-35Ni2
TH3-45Ni2
TH3-60Ni2
A
150
100
150
TH4-60Ni2
TH5-80Ni2
TH5-90Ni2
HEATER IN ISTALLATION
The heater can be placed wherever in the sauna, but for safety and convenience, follow
the minimum safety distances as provided below (See page 9). Follow the cubic
volumes given in the Technical Data (See page 32). Do not install the heater to the
floor or wall niche. Do not install more than one heater in a sauna room unless you follow
the special instructions for twin-heater installations. In most countries, there is a law that
requires heaters to be screwed to the floor.
The heater gets very hot. To avoid the risk of accidental contact with the heater, it is
recommended that a heater guard be provided.
The cable used for sauna wiring must be HO7RN-F type or its equivalent. A certified
electrician must do the installation of the heater to ensure safety and reliability. Improper
electrical connection can cause electric shock or fire. Refer to the electrical diagram (See
NOTE!
Remove the carton from the heating
elements before installing the heater
as it is only intended to protect them
during shipment.
Minimum safety distances (mm)
Minimisuojaetäisyydet (mm)
HUOM!
Poista suojapahvi vastuksista ennen
asentamista. Pahvi on tarkoitettu
ainoastaan suojaamaan kuljetuksen
ajaksi.
Kuva 2
Fig. 2
SUOMI | ENGLISH
9