Other possible problems are:

If error E4 or E6 is displayed, there is 

a problem with the bench sensor. If 

only one sensor is installed, the steam-

er cannot be used. The user can 

confirm the error by pressing the 

on/off button, after which the heater 

will function normally, but the steamer 

cannot be used. 

The user switches the steamer on and 

“dry” is displayed immediately. Check 

that the “empty” and “tank level” 

terminals from the heater are 

connected with the “empty” and the 

“tank level” in the Power Controller.
The steamer is on and “dry” is 

displayed, even though there is plenty 

of water in the tank. Make sure that 

terminals “empty” and “tank level” are 

correctly connected to the right 

terminals in the Power Controller. 
The steamer is switched on and “dry” 

is displayed immediately. Make sure 

that the “WB” terminal from the heater 

is connected with the “tank level” in 

the Power Controller. Check that the 

“UB” terminal from the Power 

Controller is connected to the “empty” 

terminal in the Power Controller.
When the user turns the steamer on 

and “Fill” is displayed continuously, the 

wiring needs to be checked. Make sure 

that the “UB” terminal from the 

controller is connected to the “empty” 

terminal in the Power Controller. In 

addition, the “WB” terminal from the 

heater needs to be connected to the 

“tank level” in the Power Controller. 
The control unit is attempted to be 

switched on with the power button and 

nothing happens or the software 

version/logo is displayed shortly. The 

problem may be low battery that does 

not have enough power to display 

“LbAt”. Change the battery inside the 

Power Controller.
Door open symbol is displayed with

high warning tone, when door sensor 

is not installed. - Check that door 

switch terminals are connected with 

each other by wire in the power 

controller. (See fig. 2/Sensors. Note 

that the connections is not present in 

the drawing.

English

The control unit is working fine, but the 

heater does not turn on. Check the 

electricity supply to the heater. Check 

that the wires for the sensors are 

placed into the correct terminals in the 

control unit.
The control unit cannot display the 

relative humidity* (only when the 

combined sensor is installed). The 

combined sensor cannot be 

recognised. The wires for the sensor 

are placed in the wrong terminals.

Control unit doesn’t turn on and 

clicking sound can be heard. Check 

that the N2 in jumper is connected with 

N (refer to technical diagram). Check 

also that fuse F1 (near transformer) is 

tightly in fuse holder.

User presses a button and “----“ is 

shown in the display. This indicates that 

the key pad is locked. Unlock the 

buttons by pressing up and down 

arrow keys at the same time for more 

than 5 seconds. A high beep will 

confirm the activation and the 

deactivation.

16

Содержание Innova Classic 2.0

Страница 1: ...CONTROLS INSTRUCTIONS MANUAL ENGLISH ...

Страница 2: ... 2 2 8 Key Pad Lock 5 3 Assembly and Installation 7 3 3 Power Controller 10 8 9 3 4 Contactor Unit 10 3 5 Sensors 11 2 3 Steamer Functions 5 2 3 1 Steamer 5 2 3 2 Water Refill 6 2 3 3 Cabin Drying 2 3 4 Automatic Drain 6 6 3 1 Control Unit to Heater Connection Diagram 7 3 6 Maximum Session Time 12 3 7 Door Sensor Optional 13 3 10 Installation for Power Controller Installation for Separate Control ...

Страница 3: ...is allowed to make electrical connections and repairs on the unit Use original parts only Disconnect the Power Controller and the Contactor Unit from the electrical circuit before installation opening the lid of the power controller or contactor unit and repair Check power supply rating before installation Check the correct location of the sensor in the installation section of the manual It is ver...

Страница 4: ...ow the corresponding LED is blinking faster Use the up and down arrows to change the value You can move from one parameter to another by short pressing the toggle button Confirm the settings by long pressing the toggle button If no keys are pressed after 5 seconds the control unit will confirm the changes automatically It usually takes around 25 40 minutes for the sauna to get warm After this you ...

Страница 5: ...the control unit is in the pre run state it will display the remaining time of the pre run The confirmed pre run settings are saved for the next session When the pre run function is used for the first time control unit estimates the time that the heater needs to reach the set temperature For example if the pre run time is set to 2 hours the heater will be switched on in 1 5 hours If the sauna has ...

Страница 6: ...l the functions and settings regarding the steamer are not available Press the mode button for less than 3 seconds to activate the steamer Once activated the steamer is switched on unless the temperature or the relative humidity inside the sauna room is too high High humidity and high temperature are not allowed HOT will be displayed in the control unit and the steamer will not be activated Lock t...

Страница 7: ... the end of the session The cabin drying session can be stopped earlier by pushing the power button 2 3 3 Cabin drying This function is activated 1 5 hours after the steamer session time or straight after cabin drying The drain function can be activated in two ways The automatic drain function can be enabled or disabled when the control unit is in OFF mode Long press the mode button and at the sam...

Страница 8: ...Built in Power Controller and Sensor The Control Panel and Power Controller communicate by using RJ12 cable 3 1 Control Unit to Heater Connection Diagram Fig 1 English 7 INSIDE THE SAUNA ROOM OUTSIDE THE SAUNA ROOM POWER CONTROLLER T H snd TS2 sensors are optional SEPARATE CONROL PANEL SENSOR S HEATER ...

Страница 9: ...A Fuse Glass Sensors Combi Steamer Steam Mate FUS TS FUS TS 1 4 2 3 FUS TS 1 4 2 3 1 4 TS1 TS2 Temperature Sensor with Fuse Optional Temperature Humidity Sensor Optional Temperature Sensor for Bench Area Contactor Unit Heater 15 kW Jumper For Maximum Session Time 4h 6h 12h 24h hours 1 JPB1 JPB1 F1 F3 F2 For Built in Controls remove the interface PCB to access the Session Time jumper Do not connect...

Страница 10: ... contactor unit Follow the instructions that are supplied together with the contactor unit 10 The Power controller or the separate control panel must not be located inside the sauna room or in places where temperature can exceed 40 C It is protected against water splashes however it should not get in contact with water Mount the Power Controller in a dry location outside the sauna room Install the...

Страница 11: ...ver the heater as shown in the figure 8 9 The optional second sensor should be mounted on the wall opposite to the heater minimum 30cm from the ceiling and minimum 130cm from the floor fig 6 8 It is designed to measure the bench temperature so ideally place it close to the shoulder height of the sauna goers Do not place the sensors near the air ventilation The closeness of the air vent cools down ...

Страница 12: ...ified electrician can change the settings The standards and regulations of the country where the control unit is installed must be followed when setting the jumpers When no jumpers are placed the default time is 6 hours See the Figure 10 IEC 60335 2 53 If you need to change the settings in the power controller with built in panel removing the control panel helps Please Note Sauna Type Domestic sau...

Страница 13: ...nsor also ensures that the door is not open for long periods of time when the heater is on If the heater is on and the door is open for more than 15minutes an alarm and DOOR will be displayed to warn the user The heater will be switched off automatically Install power controller outside sauna room in a dry place where temperature will not exceed 40C and condense of water is not possible inside the...

Страница 14: ...the top end of the unit Using this switch you can isolate the electronics from the mains power supply In order to put the unit into operation switch to the first position switch position I In this switch position all control unit s functions work normally In case of breakdown press the control unit switch on the left part of the rocker to the middle position switch position 0 The unit is now compl...

Страница 15: ...th the wires and they are correctly installed check the sensor The heater can still be used with the sensor 1 only but 2 sensors are needed for the steamer If a new sensor is needed or no reason for the problem can be found contact the retailer E4 Temperature sensor 2 is short circuit E5 Communication failure Check the RJ12 cable If the area where the cable is located has many other cables it can ...

Страница 16: ...to be connected to the tank level in the Power Controller The control unit is attempted to be switched on with the power button and nothing happens or the software version logo is displayed shortly The problem may be low battery that does not have enough power to display LbAt Change the battery inside the Power Controller Door open symbol is displayed with high warning tone when door sensor is not...

Страница 17: ...230V1N 0 5A Optional Optional Dimmeroptional Min20W max 100W Only resistiveloador dimmable phasecontrol compatible light bulb Fanwithout startingcapacitor Optional withspeed control Cabin Light Fan Description Power Rating Remarks Steamer Depending onthetypeof Sensor2 RatedPower3Phases RatedVoltage3Phases Frequency Switchingcapacityperphase 15kWAC1 3x 5kW 400V3N 50 60Hz 21A Additional Powerexpansi...