23
4Optional sauna door
safety-monitor
2. The temperature is above 40°C:
If you quickly open the sauna door (for less than 5
seconds) no message will be indicated. If the sauna
door is opened for longer than 5 seconds:
you will hear a repeated beeping sound,
the heater will be turned off
the display
4
will indicate the message
door
,
After closing the sauna door, the heater will be
turned on again.
the beeping stops,
the displayed message
door
disappears.
5
Pausing operation for a longer
time period
Turn off main fuse of the sauna control in the fuse
box.
6
Errors and possible remedies
6.1
Automatic time limitation
The sauna control turns off after 6 / 12 hours of
continuous heating (depending on factory set-
ting).
For continued operation press the START /
STOP
8
key.
6.2
Interior lighting does not work
Turn off ON / OFF
1
key.
Turn off main fuse of the sauna control in the
fuse box.
Replace light bulb.
Contact customer service or the electrical engi-
neer, if the interior light still does not work. (look
at part 1, chapter 7)
6.3
ERROR Display messages
The sauna control is not ready-to-operate:
1. Turn off main fuse of the sauna control in the
fuse box.
2. Contact customer service or the electrical engi-
neer.
3. Mark the device as defective.
With the following display error messages
4
you
can inform customer service of possible errors/de-
fects.
The error messages of the display mean:
E-F1:
Short-circuit or interrupted tempe
rature sensor line (white line)
E-24:
Excessive temperature fuse defect,
or (red) cable to excessive
temperature fuse interrupted.
E-P1:
Setting potentiometer for nominal
temperature defect.
E-51:
E-52:
Key
7
or
8
blocked
E-53:
}
Operating instructions for the user - Figure
5
www.ssb-berlin.de
Schwimmbad- und Saunatechnik Berlin - Versandhandel
Kornblumenstraße 22 - D-29725 Emden - Tel.-Nr.: 04921 - 450 99 88 - Fax: 04921 - 450 99 95