background image

3 Instructions for user

The manufacturer will not be responsible for damages
on parts of the appliance due to the use of prohibited
fuel or due to an alteration of the appliance or its
installation.

Only use replacement parts supplied

by the manufacturer.

Don’t run the stove in mild weather with
coal : Under certain circumstances (e.g. fog
and repeated thaw) the chimney will not
draw sufficiently well and thus be at the
origin of asphyxia.
Awaiting better weather circumstances,
don’t use any coal but only wood.

At the first lighting, the fire must be progressively
increased to allow the various parts to expand normally
and to dry up.

Note

: When the fire is lit for the first time, the stove may

give off fumes from the new paint. This is normal but
ensure the room is well ventilated during the first few
hours of operation.

Warning :

properly installed and operated this

appliance will not emit fumes into the dwelling.
Occasional fumes from de-ashing and re-fuelling may
occur. Persistent fume emission is dangerous and must
not be tolerated. If fume emission does persist :
Open doors and windows to ventilate room.
Let the fire go out and dispose of fuel from the
appliance.
Check for flue or chimney blockage, and clean if
required. Do not attempt to relight the fire until the
cause of the fume emission has been identified and
corrected. If necessary seek expert advice.

Note

: It is recommended to use a fireguard in the

presence of children, and also in the presence of old
and/or infirm people.

3.1 Fuel

This appliance is not an incinerator.

Use hard wood logs, which have been cut for at least
two years and stored, under a ventilated shelter.
Use hardwood that have a higher calorific value per cu
metre (Yoke-elm, oak, ash, maple, birch, elm, beech,
etc.). Large logs must be split and cut to an useful
length, before being stored in a sheltered and ventilated
place.

Recommended fuel :

T h e b e s t f u e l s f o r u s e w i t h t h e F r a n c o B e l g e
“Savoy MK2” are :
Seasoned wood. - hard wood logs that have been cut,
split and stored for at least two years with a maximum
moisture content of 20 % e.g. oak, beech, elm etc.

Fuel : smoleless fuel

Heating volume . . . . . . . . . . . . . . . . m

3

. . . . . . . . 240

Firebox draught at nominal . . . . . . . Pa . . . . . . . . 12
Nominal heat output. . . . . . . . . . . . . kW. . . . . . . . 7
Efficiency . . . . . . . . . . . . . . . . . . . . . %. . . . . . . . . 70
CO (13 % O2) . . . . . . . . . . . . . . . . . . %. . . . . . . . . 0,13

Mean flue gas temperature

. . . . . . . C° . . . . . . . . 250

Anthracite – dry steam coal fuels as described in type A
– table B2 of the Standard – smokeless fuels along with
coalite and anthracite.

Prohibited fuel :

Any form of housecoal (bituminous coal) or petroleum
based fuels.
We do not recommend that unseasoned wood (green
wood) is used due to it’s high levels of moisture which
will produce tar and in turn can cause the insides of the
stove and the lining of the chimney to become coated
which in turn could lead to a chimney fire.
We do not recommend recovered wood e.g railway
sleepers,chipboard, pallets are burned as these have
been treated and will product a great deal of pollution to
the environment and will overheat the appliance.

Technical manual “1274”

7

“SAVOY MK2” - model : 134 08 09

Instructions for user

+

*  

*

)

Figure

 7

-

Operating devices

A

: Opening/closing the

main door

B

: Draught control

(secondary air inlet)
B1 = Flue damper opened
B2 = Flue damper closed

C

: Primary air inlet

Содержание MK2 ELEGANCE 134 08 09

Страница 1: ...ertificate Document n 1274 8 20 09 2011 Multifuel stove Norm DIN EN 13240 2005 10 Model 134 08 09 Output 8 kW Technical manual to be saved by the user for future reference FR EN NL IT SAVOY MK2 ELEGANCE ES Rue Orphée Variscotte 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 38 Fax 00 333 28 43 48 60 ...

Страница 2: ...eant to burn wood or solid fuel safely WARNING Incorrectly installed this appliance can be dangerous and possibly cause serious accidents We recommend that you engage the services of a professional engineer for its installation and the regular maintenance requirements Door closing pressure p 6 ...

Страница 3: ...ity with DIN EN 13240 2005 10 Intermittent burning heating appliance Detachable flue spigot for rear or top chimney connection Front loading door fitted with large refractory glass panel Adjustable primary air for controlling the burning rate Large ash pan 1 4 Operating principle The appliance is designed for operating only with the door closed Heat is mainly diffused by radiation through the wind...

Страница 4: ...ute this load Make sure they are not combustible or covered with combustible material as per the Building regulations There must be a clearance of at least 150 mm at each side of the appliance and at the back of the appliance from a non combustible wall This measurement may be reduced to a minimum gap of 50 mm when the non combustible wall is at least 200 mm thick This distance must be extended to...

Страница 5: ... combustible material walls cross members It must permit an easy sweeping 2 4 Mounting the flue collar The stove is supplied with a connection flue spigot with an inner diameter of 125 mm and an outer diameter of 139 mm The stove is set from the factory with a top outlet 2 5 Top flue outlet Figure 3 First remove the flue baffle A The stove is set from the factory with a top outlet Do not remove th...

Страница 6: ...re utilisation check Check that the seals of the smoke line are in good condition Check that the door closes correctly Check that the glass is not damaged Check that the smoke passages are not obstructed by packaging or removable parts Check that all removable parts are correctly installed Note The rope seals should be checked on a regular basis as they are normal replacement parts 2 10 Maintenanc...

Страница 7: ... or infirm people 3 1 Fuel This appliance is not an incinerator Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter Use hardwood that have a higher calorific value per cu metre Yoke elm oak ash maple birch elm beech etc Large logs must be split and cut to an useful length before being stored in a sheltered and ventilated place Recommended fuel The be...

Страница 8: ...gard to the live embers 3 5 Maintenance of the Chimney Very important In order to avoid any incident chimney fire etc maintenance tasks must be carried out regularly If the appliance is regularly used the chimney should be swept several times per year together with the stovepipe connection section If the chimney catches fire you must cut off the flue draught close the doors and windows hatches and...

Страница 9: ...all wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up The flue damper is closed Open the flue damper Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pressure In houses equipped with mechanical ventilation partly open a window until the fire is well established Smokes while burning Insufficient draught Open temporaril...

Страница 10: ...10 Technical manual 1274 SAVOY MK2 model 134 08 09 Note Note ...

Страница 11: ...236138 Reducing plate A B C D 01 23 237406 Reducing plate A B C D 01 24 237427 Reducing plate A B C D 01 25 259015 Fixing plate A B C D 04 26 262607 Heat shield A B C D 01 27 270402 Air control flap A B C D 01 29 300128 EF Leg A 04 29 300128 RH Leg B 04 29 300128 RP Leg C 04 29 300128 MK Leg D 04 30 300446 EF Base A 01 30 300446 RH Base B 01 30 300446 RP Base C 01 30 300446 MK Base D 01 31 301526 ...

Страница 12: ...Technical manual 1274 SAVOY MK2 model 134 08 09 Spare parts Figure 8 Spare parts view 20 50 21 7 51 51 6 0 52 ...

Страница 13: ...1 42 327910 MK Tray D 01 43 331132 EF Main door A 01 43 331132 RH Main door B 01 43 331132 RP Main door C 01 43 331132 MK Main door D 01 44 332004 Air duct A B C D 01 45 352176 EF Top plate A 01 45 352176 RH Top plate B 01 45 352176 RP Top plate C 01 45 352176 MK Top plate D 01 46 406816 Clamp A B C D 01 47 415504 60 Poker A B C D 01 48 624042 Ash pan A B C D 01 49 808001 ED Hand tool A B C D 01 N...

Страница 14: ...the exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in contact with high temperatures namely soles and burner grills bottom plates baffles ash pans paintwork and surface treatments for decorative parts Also excluded from this guarantee are seals and ...

Отзывы: