background image

4

Figure 6

Figure 7

Registration slot

5. HANGING THE FAN

REMEMBER

 to turn off the power. Follow 

the steps below to hang your fan properly.

NOTE:

 This ceiling fan is supplied with two 

types of hanging assemblies; the standard 
ceiling installation using the downrod with 
ball and socket mounting and the 
"close-to-ceiling" installation. The "close-to 
-ceiling" installation is recommended in 
rooms with less than 8-feet ceilings or in 
areas where additional space is desired 
from the floor to the fan blades. 
 

STANDARD CEILING INSTALLATION

Step 1.

 Pass the 120-volt supply wires 

through the center hole in the ceiling 
hanger bracket as shown in Fig. 5.

Step 2. 

Secure the hanger bracket to the 

ceiling outlet box with the screws and 
washers provided with your outlet box.

Step 3.

 Remove the hitch pin, lock pin and 

set screws from the top of the motor 
assembly.

Step 4.

 Route wires exiting from the top of 

the fan motor through the canopy and 
then through the ball/ downrod. (Fig. 6)

Step 5.

 Align the holes at the bottom of 

the downrod with the holes in the collar on 
top of the motor housing (Fig.6). Carefully 
insert the hitch pin through the holes in 
the collar and downrod. Be careful not to 
jam the pin against the wiring inside the 
downrod. Insert the locking pin through 
the hole near the end of the hitch pin until 
it snaps into its locked position, as noted in 
the circle inset of Fig. 6. 

Step 6.

 Tighten two set screws on top of 

the fan motor firmly. (Fig. 6)

Step 7.

 Place the downrod ball into the 

hanger bracket socket. (Fig. 7)

Figure 5

Downrod

Set screws

Lock pin

Hitch pin

Tab

Mounting screws
(supplied with
electrical box)

UL Listed
electrical box

Hanger 
bracket

Canopy

Содержание 52-ECM-589-89

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V 60Hz UL LISTED MODEL AC 552 CEILING FAN OWNER S MANUAL MODELS 52 ECM 5RV 13 52 ECM 5RV WH 52 ECM 5RV SN 52 ECM 5RV 13WG 52 ECM 589 89 ...

Страница 2: ...ll chains and fobs 2 k Extra plastic plug l Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 16 fiber washers 16 3 Blade arm hardware screws with lock washers 11 4 Safety cable hardware wood screw lock washer metal washer 5 Balance Kit 1 Philips screwdriver Blade screwdriver 11 mm wrench Step ladder W...

Страница 3: ...des to the floor 7 Do not operate reversing switch while fan blades are in motion Fan must be turned off and blades stopped before reversing blade direction 8 Avoid placing objects in the path of the blades 9 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry d...

Страница 4: ...eight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet box...

Страница 5: ...ers provided with your outlet box Step 3 Remove the hitch pin lock pin and set screws from the top of the motor assembly Step 4 Route wires exiting from the top of the fan motor through the canopy and then through the ball downrod Fig 6 Step 5 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 6 Carefully insert the hitch pin through the holes...

Страница 6: ...e the ceiling canopy over the collar at the top of the motor Align the mounting holes with the holes in the motor and fasten using the screws and lock washers provided Fig 9 6 Tighten the mounting screws securely WARNING Failure to completely tighten the three screws in step 5 could result in fan loosening and possibly falling 7 Hang the fan on the hook of the hanger bracket Be certain that the ca...

Страница 7: ...ecting nuts upward and push the wiring into the outlet box Figures 12 and 13 illustrate the wiring connections for optional wall control The wire color out of wall control may vary see wall control s installation manual for correct wire connections Figure 11 Figure 12 Figure 13 WH BLUE BLK WH GRN WIRING BOX GROUND TO MOUNTING BRACKET OR DOWNROD BLUE BLK WH WH FAN LIGHT POWER LINES 120V BLK GREEN G...

Страница 8: ... the canopy to the hanger bracket with the four screws with your fan CLOSE TO CEILING INSTALLATION Remove the fan from the hook on the hanger bracket Secure the canopy to the hanger bracket as shown in Figure 15 with four screws included with your fan Figure 14 Figure 15 Outlet box Hanger bracket Screws Ceiling canopy Canopy ring Outlet box Hanger bracket Ceiling canopy Screws ...

Страница 9: ...ing the screws supplied Fig 16 9 INSTALLING THE LIGHT KIT NOTE Before starting installation disconnect the power by turning off the circuit breaker or removing the fuse at fuse box Step 1 Remove the 3 screws from the mounting plate Step 2 While holding the light kit under your fan snaptogetherthewireconnectionplugs Fig 18 Step 3 Install the light kit onto the mountimg plate with 3 screws provided ...

Страница 10: ...ower and your light kit is ready for operation NOTE Make sure to leave enough space between the fan pull chain and the bulbs so the chain doesn t rub against any of the bulbs 11 FAN WITHOUT LIGHT KIT OPTIONAL 1 Disassemble the switch housing from the light kit by removing nut and washer on the center of switch housing you can keep the light kit for future use 2 Attach the plastic plug to the switc...

Страница 11: ...or warm or cool weather depend on factors such as the room size ceiling height number of fans and so on The slide switch controls directions forward switch down or reverse switch up Warm weather Forward A downward airflow creates a cooling effect as shown in Fig 20 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow ...

Страница 12: ...ontrol s 7 Make sure the upper canopy is a short distance from the ceiling It should not touch the ceiling 1 Check that all blade and blade arm screws are secure 2 Most fan wobbling problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance Rotate the fan until the next blade is positioned for meas...

Отзывы: