INSTALLATION
Drilling the Support surface and Fitting the Hood
• The Hood can be fitted directly on the low-
er surface of the Wall Units using the snap-
on Side Supports.
• Make an opening on the lower surface of
the Wall Unit, as indicated.
• Insert flange
9
into the top exhaust opening.
• Screw the closing profile
20
onto the rear
part of the hood, using the screws
12e
(2.9
x 12.7) provided.
• Open the comfort panel by turning the
knobs provided.
• Open the glass panel.
• Disconnect the lights connector.
• Disconnect the panel from the hood canopy
by sliding the lever out of the fixing pin,
simultaneously freeing the other end of the
panel from the fixing pin.
• Remove the metal grease filters one at a
time, by turning the hooks provided.
• Close the glass panel again.
• Insert the Hood until the snap-on side sup-
ports click into place.
• Open the glass panel.
• Lock in position by tightening the screws
Vf
from underneath the Hood.
• If necessary, adjust the whole filter holder
unit and proceed as follows:
• Loosen the four adjustment screws
Vr
and close the glass panel again.
• Move the entire filter holder unit until it
is properly aligned with the wall unit.
• Keeping the hood canopy still, remove
the glass panel and lock the adjustment
screws again.
• The hood can now be fastened to the
wall unit using the four screws
12a
(3.5
x 16) provided.
• Replace the metal grease filters.
• Connect the lights connector.
• Close the glass panel again and hook up the
comfort panel.
162
503
Vf
Vr
12e