EXHAUSTING (EXTERNAL MOTOR) 

Use the non-return valve 

L

 at the beginning of 

exhausting flue. This prevents cold air flow to room 
when motor is not on. 

 

Connect to 150mm flue in order to get the best 
performance out of the hood. Flue must be as straight 
and short as possible. (flue not included) 

 

Make sure that flue is properly isolated. 

 

If the flue is diam. 125mm, use the outlet reduction 

S

Flue diam. under 125mm is not recommended. 
(too big counter pressure might damage the motor) 

CONNECTING 

Check that hood and external 
motor are compatible. 
 
Manufacturer is not liable 
for misinstallations! 

 

Important !    

Connecting to external motor: 

• 

Text on lid 

B

 ”EXTERNAL MOTOR” 

• 

Check the wire connections  

• 

Yellow/green  (      ) ground

 

• 

Blue ( 

N

 ) neutral

 

• 

Red  ( 

L

 ) line

 

 

Requires closed circuit installation !  

Power input: 

• 

White 150cm pre-installed cable 

• 

Check the wire connections 

• 

Yellow/green  (      ) ground

 

• 

Blue ( 

N

 ) neutral

 

• 

Brown ( 

L

 ) line 230V

 

Mount the upper cover duct to the bracket with 2 
screws. Lift up lower duct and secure with a screw. 
Mount the hood to the telescopic structure with 4 crews. 
 
Mount the exhausting flue to the hood from hole 

D

 
Let down the lower duct. 
Replace grease filters. 
Connect to power network. 