Mounting the Tag

1.

Open the right door of the container.

2.

Using both hands, push the C-clamp on the tag onto the edge of  the 

left

 door until it is on as far as it can go.

Left door outside view

Left door inside view

3.

Close the right door.

Содержание ST-656

Страница 1: ...Installation Guide Savi ST 656 Data Rich Tag with Container Door Mount ...

Страница 2: ...ordance with the terms of the agreement It is against the law to copy the software on any medium except as specifically allowed in the license or nondisclosure agreement THIS DOCUMENTATION CONTAINS CONFIDENTIAL INFORMATION AND TRADE SECRETS OF SAVI TECHNOLOGY INC USE DISCLOSURE OR REPRO DUCTION IS PROHIBITED WITHOUT THE PRIOR EXPRESS WRITTEN PERMIS SION OF SAVI TECHNOLOGY INC U S GOVERNMENT RIGHTS...

Страница 3: ...ST 656 Data Rich Tag Description 5 Features 7 Activating the Tag 7 Initializing the Tag 9 Placing the Tag for Best Performance 10 Mounting the Tag 12 Replacing the Battery 13 Contacting Savi Support 14 Specifications 15 ...

Страница 4: ...4 ...

Страница 5: ...e through the global supply chain The ST 656 tag s unique C clamp door mount design places the sensitive RFID components inside the shipping container Only the low profile external antenna casing is on the outside of the container which significantly reduces the risk of tag damage during the loading unloading and transportation of shipping containers Figure 1 Savi ST 656 Container Security Tag Fro...

Страница 6: ...Savi ST 656 Container Tag Installation Guide 6 Figure 2 Top view Door Clamp Antenna Outside Inside Figure 3 Rear view Tag ID number USB port Model number Battery compartment ...

Страница 7: ...onal line of sight range Replaceable battery with typical life of five years Supports low frequency technology for more precise locating capabilities Supports USB operation for reading and writing FCC HERO ETSI RoHS Directive 2002 95 EC certified Activating the Tag The tag is shipped in sleep mode You must remove and re insert the battery to wake up the tag After you re insert the battery you can ...

Страница 8: ...tion Turn to open Correct battery orientation Whenever a battery is inserted into a tag the tag will emit 5 beeps Then if the tag emits a long 1 2 second beep that means it has an internal sensor failure Then the tag will emit 2 short beeps to indicate adequate battery voltage or 3 short beeps if a fresh battery is required Whenever a battery is inserted into a tag the tag assumes that it is a fre...

Страница 9: ...e cap water leakage and damage may occur Note When the tag is not in use disable the tag by removing reversing and re inserting the battery Store the battery at room temperature 50 80 F or 10 27 C Initializing the Tag Once you activate the tag you can initialize it for immediate use 1 Unplug the USB port cover 2 Insert the USB cable into the USB port on the tag and connect the other end to the USB...

Страница 10: ...chnology recommends that you mount the tag on a flat surface with the tag aligned vertically For best performance place the tag as high as possible safe from impact for example between the ribs of an ISO type shipping container and away from obstructions on the asset For best performance make sure the tag is Mounted on a metal surface Mounted at no less than a 6 foot 1 8m elevation Mounted vertica...

Страница 11: ...ote Make sure you clean the surface of the container or other asset before attaching the tag The tag will have 400 foot 122m read write range to Savi SR 650 Fixed Readers For the most consistent communications with the tag the Fixed Readers must be mounted to have an unobstructed line of sight to the tag at 20 feet 6m or higher Follow the instructions in the Savi Fixed Reader documentation to loca...

Страница 12: ...ide 12 Mounting the Tag 1 Open the right door of the container 2 Using both hands push the C clamp on the tag onto the edge of the left door until it is on as far as it can go Left door outside view Left door inside view 3 Close the right door ...

Страница 13: ...f you install the battery in the wrong direction reversed 4 Replace the battery cap on the tag Whenever a battery is inserted into a tag the tag will emit 5 short beeps one second apart Then if the tag emits a long 1 2 second beep that means it has an internal sensor failure Remove the battery and insert it again If the tag emits the same long 1 2 second beep do not use the tag Then the tag will e...

Страница 14: ... information Send an email to help savi com Call 1 888 994 SAVI North America only or 1 650 316 4760 between 5 a m and 5 p m Pacific time When you contact Savi Support Services by telephone or email have the following information available Contact information company name your name email and phone number Problem description Software version Product type Serial number or license information ...

Страница 15: ...ontainer ISO 668 1995 E Series 1 Freight Containers Color Black Environmental Temperature 32 C to 70 C operating 40 C to 85 C storage Humidity 95 non condensing Vibration and shock MIL STD 810F Weatherproofing IP64 Manufacturing RoHS Directive 2002 95 EC Wireless UHF Transceiver Frequency 433 MHz Range 400 ft 122 m operating read write range outdoors non obstructed from Savi SR 650 reader Protocol...

Страница 16: ...tal Database memory On board non volatile memory 128 Kb Wired interface USB 1 1 USB 2 0 Mounting C clamp Clamps easily onto shipping container left door edge frame C clamp to left door Mount tag anywhere on the edge of the left hand container rectangular doorframe measuring 2 in 50 mm x 4 in 100 mm Approvals Radio Type Approval FCC Part 15 EN 300 220 433 MHz EMC and immunity EN 301 489 Ordnance HE...

Отзывы: