background image

C H A P T E R

   

Introduction

10

SaviTag ST-614/ST-615 Installation Guide

Model Description

Part number: ST-614-001 and ST-615-001

Description: SaviTag ST-614-001 and SaviTag ST 615-001

Onboard memory: 1K Serial EEPROM – User memory

Contacting Customer Support

If you cannot find the information you need in this guide, contact Savi 
Customer Support.

Call 1-888-994-SAVI (North America only) or 1-408-743-8888 
between 9 a.m. and 5 p.m. Pacific time.

Regulatory approvals

Radiated emission (intentional): U.S. emissionstandards as 
contained in FCC Part 15 subclauses 15.231a, 15.231e, and 
15.240. European Community emission standards as 
contained in EN 300 220-1 (433 MHz) and EN 301 489-1. 
Korean MIC regulation 2005-50 (433 MHz). Compliance 
with ISO 18000-7 specifications
Electromagnetic immunity: 80 MHz to 1,000 MHz, 3 V/m 
in accordance with EN 301 489-1.
ESD compliance: Exposed to 8 kV air discharge or 4 kV 
contact discharge in accordance with EN 301 489-1.
Radiated emission (unintentional): U.S. emissions 
standards as contained in FCC Part 15 and European 
Community emission standards as contained in EN 301 
489-1
Ordnance Safety (ST-614 only): HERO Certification at 4” 
distance. Self-certified at 1” distance through ARDEC.
Markings: Savi Name & Logo, Product Model Number, Serial 
Number, ARDEC / HERO Label (ST-614 only), EMC 
Compliance Label.

Mounting

Pressure-sensitive tape mounting kit

Magnetic mounting kit

Software

Savi SmartChain® Site Manager, Retriever, or Savi 
SmartChain® Client Tools 4.0

Specification

Description

Содержание SaviTag ST-614

Страница 1: ...Installation Guide SaviTag ST 614 ST 615 Version 0 1...

Страница 2: ......

Страница 3: ...rms of the agreement It is against the law to copy the software on any medium except as specifically allowed in the license or nondisclosure agreement Savi Savi SmartChain SmartChain and Batch Collect...

Страница 4: ......

Страница 5: ...ioning SaviTag ST 614 ST 615 13 Conserving the Battery 15 Low Battery Warning 15 Avoiding Overpolling 15 Placing the Tag 17 Example Asset Mounting Locations 18 Mounting SaviTag ST 614 ST 615 19 Mounti...

Страница 6: ...6 SaviTag ST 614 ST 615 Installation Guide...

Страница 7: ...life using lithium cells is typically five years SaviTag ST 614 ST 615 is also certified as safe for operation with live ordnance Features 433 MHz active RFID technology with up to 270 foot 82 3 m ra...

Страница 8: ...on condensing Salt fog MIL STD 810F Method 509 4 Low pressure altitude MIL STD 810F Method 500 4 Maximum altitude 40 000 ft RF receiver transmitter Ultra High Frequency transceiver Frequency 433 92 MH...

Страница 9: ...protocol Savi EchoPoint Air Protocol 1 1 Network Wireless RF read write capable Memory Onboard non volatile memory 1K Antenna Internal UHF Omni loop antenna Shock and vibration Shock MIL STD 810F 514...

Страница 10: ...1 433 MHz and EN 301 489 1 Korean MIC regulation 2005 50 433 MHz Compliance with ISO 18000 7 specifications Electromagnetic immunity 80 MHz to 1 000 MHz 3 V m in accordance with EN 301 489 1 ESD compl...

Страница 11: ...om Check www savi com support for information When you contact Savi Customer Support by telephone or email have the following information available Contact information company name your name email and...

Страница 12: ...C H A P T E R Introduction 12 SaviTag ST 614 ST 615 Installation Guide...

Страница 13: ...a handheld rivet gun Commissioning SaviTag ST 614 ST 615 You can commission SaviTag ST 614 ST 615 using the low frequency UHF interface You can send a low frequency command from SmartChain Mobile Man...

Страница 14: ...615 14 SaviTag ST 614 ST 615 Installation Guide 3 Select Enable Disable Tag UHF Receiver Savi SmartChain Mobile Manager searches for and displays a list of all SaviTag ST 614 ST 615 within range and i...

Страница 15: ...sing through overpolling Low Battery Warning The battery will last approximately three to five years When the battery is too low to support two complete shipments the tag will report a low battery mes...

Страница 16: ...ponding to tag collections from any fixed or mobile reader initiating UHF collection commands To put the SaviTag ST 614 ST 615 to sleep using the SmartChain Mobile Manager follow these steps Note Smar...

Страница 17: ...T 614 ST 615 follow the steps outlined for taking the SaviTag out of storage mode as described in Commissioning SaviTag ST 614 ST 615 on page 13 Placing the Tag Savi Technology recommends that you mou...

Страница 18: ...be mounted To have an unobstructed line of sight to the tag At 20 feet 6 meters or higher With the reader dome pointed downward Example Asset Mounting Locations M3 Container Roll in out Platform CROP...

Страница 19: ...by sudden impact vibration or shock during transport The fastener you choose often depends on the material from which the asset or container is constructed and your personal preference SaviTag ST 614...

Страница 20: ...tant that you follow proper surface preparation to enable optimal adhesion PST is not intended for attachment to wooden surfaces because of the surface roughness of wood and the wicking of rain or spr...

Страница 21: ...e following cleaning materials available General purpose cleaner Any commercial cleaner with a degreaser for example Formula 409 Cleaner Ajax All Purpose Cleaner or Simple Green All Purpose Industrial...

Страница 22: ...Guide 3 Using rags or paper towels clean the mounting surface so it is free of dirt rust and loose paint flakes 4 If the surface is heavily soiled use a mild soap and water solution to scrub the surf...

Страница 23: ...shipping container or asset the location of the rivet holes on the tag 3 On the asset drill holes at the locations you marked in step 2 4 Return to the location where the tag is to be attached to the...

Страница 24: ...thods You can mount SaviTag ST 614 ST 615 using some or all of the fasteners listed on page 19 You will need to provide your own rivets or screws Figure 6 SaviTag ST 614 ST 615 mounting holes The tag...

Страница 25: ...that you leave the tag attached to the asset for later reuse but if it is necessary to remove the tag 1 Lift one end of the RFID tag with a putty knife or chisel and separate the tape 2 Remove the ta...

Страница 26: ...C H A P T E R Installing SaviTag ST 614 ST 615 26 SaviTag ST 614 ST 615 Installation Guide...

Страница 27: ...T Extreme temperature 40 to 70 Celsius Step test 200 pounds applied in shear Shock 140g or 120 lbs Vibration MIL STD 810E Salt fog MIL STD 810E Corrosive liquids Peel test 50 pounds of peel force Savi...

Страница 28: ...C H A P T E R Appendix A PST Reliability and Durability 28 SaviTag ST 614 ST 615 Installation Guide...

Отзывы: