![SAVE MARINE H240 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/save-marine/h240/h240_installation-manual_1203763017.webp)
7
Save Marine, a division of
Save innovations
3 rue des arts et métiers, 38000 Grenoble, France I +33 (0)4 58 00 34 66 I [email protected]
4-
Strengthen the transom if necessary and set up the location for the counter-plate
(responsibility of the installation company). Check that there is enough room available
to access the fixing screws.
5-
A clearance of 30 cm above the home plate should be free to put in place and pull the
hydrogenerator.
6-
A space of 10 cm is necessary between the hull and the profile arm of the hydro.
Mark the location for the subsequent fixing.
Positioning schematic
Clear space : 30 cm
M6x60 screw
M6 nut
Counter-plate
(under installer responsibility)
Home plate
Boat hull
Clear space
10 cm