4
2. FUNCTION INTRODUCTION
Item
Function
Description
Remark
Common function
1
Floor service
The system supports the floor service not more than 32 floors.
2
Power supply
management
When there is no operation and the time reach to the power
management set, turn off the car lights and fans to save energy.
3
Bell time switch
When the function is opened, during the setted time, the bell is
ready. Exceed the setted time, the function is off in case of
disturbing, and save energy.
4
Collective selective
control
Set the full selective, up selective, Down selective.
5
Homing floor
If elevator without operation time is over homing time, elevator
records the homing floor and back to the homing floor to wait.
6
Floor stop setting
Flexible to set stopping at some floors, others do not stop.
7
Open door set for front
door and back door
Flexible defining some floors open in front door, some floors open
back door, and others open front and back doors.
8
Floor display set
Set the display code for floors.
9
Reverse cancelling
When the running direction changed, system cancels all car
callings.
10
Re-leveling when the
door is open
The lift stop at the floor station, a large number of persons or
goods entering and leaving, The leveling fluctuated because of the
elastic deformation of elevator Wire Rope and the rubber. System
allows run automatically at the speed of re-leveling to leveling
station in the state of the door opened.
11
Full load by pass
When the car with full load the elevator does not respond to hall
calls, but only car calling.
12
Button stuck check
The system can automatically judge the button stuck situation at
hall calling and remove the stuck calling.
13
Cancel the wrong
direction
Passengers can press the command button continuously(within 3
seconds) twice in the control box to cancel the last error
registration instructions.
14
Anti-nuisance
If the car is at normal duty and there is more than 3 commands, the
system will cancel all car callings.
15
Light Curtain checking
During close, when light curtain is blocked, the action of closing
will turn to opening.
16
Extend close in
During opening, if users press extend close button, the time of clo
sing will be extended, which is set according to parameter.
Содержание SEC-M500
Страница 1: ...SEC M500 Elevator Controller User manual User Manual ...
Страница 24: ...21 4 2 2 Spare input X21 function set ...