CHAPTER 3 LIST OF DESCRIPTIONS FOR FUNCTIONAL PARAMETERS
0. User’s parameters
set during running available
Parameter
Parameter functions
Setting range
Factory
setting
0-00
Inverter type code recognition
(Only for Reading)
4:220V/0.4kW
5:220V/0.75kW
Factory
setting
0-01
Rated Current Display for
Inverter (Only for Reading)
220V/0.4kW:2.5A
220V/0.75kW:4.2A
Factory
setting
0-02
Data initialization
10: Parameter reset to factory setting
0
0-03
Machine ON Display Selection
0: F(Display set frequency reference)
1: H(Display actual running frequency)
2: U (Display multi-function determination)
3: A(Display motor running current)
4: P(Master frequency display)
5: b(Auxiliary frequency display)
0
0-04
Determining multifunctional
display
0: Displaying output physical quantity(u)
defined by operators
1: Displaying count value (c)
2: Displaying program operation content (X=tt)
3: Displaying DC-BUS voltage(U)
4: Displaying output voltage (E)
5: Displaying rotating speed(r )
6:
Reserved
7: Module temperature
8: Charging resistance temperature
9: Display the current carrier frequency
0
0-05
Proportional constant setting
0.1 to 160
1.0
0-06
Software Version
Only for reading
#.##
0-07
Input parameter password
protection
0 to 999
0
0-08
Setting parameter password
protection
0 to 999
0
1. Basic Parameters
Set during running available
Parameter Parameter functions
Setting range
Factory
setting
1-00
Max operation frequency
setting
5.0 to 400Hz
50.0
1-01
Maxi voltage frequency setting 10.0 to 400.0Hz
50.0
1-02
Maxi output voltage setting
2.0 to 255.0V
220
1-03
Intermediate frequency setting 0.1 to 400Hz
0.5
1-04
Intermediate voltage setting*
2.0 to 255V
12.0
1-05
Min output frequency setting
0.1 to 60.0Hz
0.5
1-06
Output voltage at starting
frequency
2.0 to 255V
12.0
1-07
Frequency limiter(Upper)
1 to 110%
100
1-08
Frequency limiter(Lower)
0 to 100%
0.0