13
Part No. 001188, 08-m05-2020
K2 Plus Stairlift Owner’s Manual
Diagnostic LEDs
There are three diagnostic LEDs located on the carriage front panel.
B355 and B613 units DO NOT have the 3 diagnostic LEDs.
Figure 5
NOTE
LED Status
LEDs
Meaning
Middle and right LEDs on
Left-hand obstruction (or ready to run right)
Middle and left LEDs on
Right-hand obstruction (or ready to run left)
Middle LED on
Obstruction, both right-hand and left-hand
All LEDS off
Safety circuit fault
All LEDs on
Ready to run left or right
Maintenance
The owner can perform the 3-month checks; however, the
6-month checks and other maintenance
must
be performed
by a qualified technician. Contact your Savaria dealer.
Units installed in adverse environments will require additional
maintenance on a monthly basis.
SAFETY CIRCUIT FAULT (SEE OWNER’S MANUAL)
LH OBSTRUCTION (OR READY TO RUN RIGHT)
RH OBSTRUCTION (OR READY TO RUN LEFT)
OBSTRUCTION, BOTH RH AND LH
READY TO RUN LEFT OR RIGHT
NOTE