Part No. 000783, 24-m09-2015

Infinity and Infinity HD Planning Guide

Infinity/Infinity HD specifications

2-

Specification type 

Specification data

Load capacity

Infinity: 750 lb (341 kg), 950 lb (431 kg) or 1000 lb (454 kg)

Infinity HD: 1400 lb (635 kg)

Rated speed

36 ft/min (0.18 m/s) nominal

Maximum travel

50 ft (15.24 m) – confirm with local code

Maximum # of stops

6 stops

Pit depth required

Infinity: 8” (203 mm) minimum up to 96” (2438 mm)

Infinity HD: 12” (305 mm) minimum up to 96” (2438 mm)

Minimum overhead clearance 

92” (2337 mm) for standard 80” cab; 96” (2438 mm) for 84” cab, 108” (2743 mm) for 96” cab

Power supply (circuit to be supplied by others)
NOTE: Amperage may vary depending on 
individual units. Verify requirements prior to 
installation of power supply.

North American: 208 volt, three-phase, 30 amps, 60 Hz or 230 volt, single-phase, 30 amps, 60 Hz
NOTE: 60 Amps for Infinity HD
International: 220 volt, single-phase, 40 amps, 50 Hz

Lighting supply (circuit to be supplied by 
others)

North American: 115 volt, 60 Hz, 15 amps
International: 220 volt, 50 Hz 15 amps

Motor

Infinity: 3 HP (2.24 kW)

Infinity HD: 5 HP (3.73 kW)

Drive system

1:2 cable hydraulic

Control system

Automatic user interface

Solid state electronics with relay logic motor controls

Noise level (for typical installation)

74.0 dBA; measured at a height of 1m, distance of 1m, in front of tank, in closed machine room

Daily cycle

Normal: 30

Heavy: 75

Excessive: 100

Maximum starts in 1 hour on standard installation: 15

NOTE: Please consult your Sales Representative if there a chance you may exceed these amounts.

Cab size

Infinity Type 1L, 1R, 2, 3, 4, and 5:
• 36” x 48” (914 mm x 1219 mm)
• 36” x 54” (914 mm x 1372 mm)
• 36” x 60” (914 mm x 1524 mm)
• 40” x 54” (1016 mm x 1372 mm)
Infinity HD Type 1L, 1R, 2, 3, 4 and 5:
• 48” x 60” (1219 mm x 1524 mm)

Cab panel finish

Solid melamine or MDF panels (standard)

Unfinished veneer (optional)

Solid hardwood raised panels (optional)

Hall call station and control panel finish

Clear or bronze anodized aluminum (standard)

Stainless steel or brass (optional)

Rectangular (standard) or oval (optional) hall stations, keyless (standard) or keyed (optional)
Alpha-numeric button marking (optional)

Standard features

Anti-creep device
Automatic cab on/off lighting
Cab gate safety switch
Car top stop switch
In car digital floor indicator
Clear or bronze anodized aluminum cab entrance trim and handrail
Data plates, capacity tags and rope tags
Emergency stop and alarm buttons
Emergency battery back-up for lighting, alarm and emergency lowering 
Upper and lower terminal limits
Magnetic floor selection, stopping and re-levelling
Manual reset slack rope safety switch
Mechanical rail shoring blocks
Negative pressure switch
Pit switch
Pump run timer
Rail sections (8 ft optional or 16 ft standard)
Two 12 V, 4 AH, sealed no maintenance batteries with 24 V, 4 amp Smart Charge™ battery charge
Unfinished plywood sub-floor
Variable speed pressure compensated valve with manual lowering 
White ceiling with recessed incandescent down lights

Options

84” (2133 mm) or 96” (2438 mm) high cab

Automatic gate operator (accordion gates only)

Automatic swing door operator
Phone cabinet
Hose with flow control valve (15 ft, 20 ft or 25 ft)
Interlocks for doors by others
Keyed on/off control panel and hall stations
Light screens
Pipe rupture valve
Buffer springs (13” pit depth minimum)

Split cylinder for travel over 384” (9754 mm)
Auto slim doors

Содержание Infinity

Страница 1: ...nity HD RESIDENTIAL ELEVATORS Planning Guide Applicable Codes ASME A17 1 CSA B44 Safety Code for Elevators and Escalators Section 5 3 Private Residential Elevators Part No 000783 24 m09 2015 2015 Savaria Corporation ...

Страница 2: ...Copyright 2015 Savaria Corporation All Rights Reserved Printed in Canada ...

Страница 3: ...th Auto Slim Doors planning information April 19 2011 Updated Auto Slim Door entrance assembly and elevation drawings in Appendix A August 12 2011 Revised Auto Slim Door entrance assembly drawings in Appendix A September 15 2011 Revised Auto Slim Door entrance assembly drawings in Appendix A August 30 2012 Revised Auto Slim Door elevation and plan view drawings in Appendix A November 6 2012 Added ...

Страница 4: ...ity Guidelines as a means to provide public building access Design assistance With over 30 years of experience Savaria has the expertise to provide solutions to practically every design challenge you face Please call our Customer Service Department for professional advice at 800 661 5112 or 905 791 5555 Cab Cab operating panel COP Overhead clearance Hydraulic cylinder Guide rails Aircraft cables I...

Страница 5: ... 3 4 and 5 36 x 48 914 mm x 1219 mm 36 x 54 914 mm x 1372 mm 36 x 60 914 mm x 1524 mm 40 x 54 1016 mm x 1372 mm Infinity HD Type 1L 1R 2 3 4 and 5 48 x 60 1219 mm x 1524 mm Cab panel finish Solid melamine or MDF panels standard Unfinished veneer optional Solid hardwood raised panels optional Hall call station and control panel finish Clear or bronze anodized aluminum standard Stainless steel or br...

Страница 6: ...y Infinity HD cab types 3 4YPE 4YPE 2 4YPE 4YPE 4YPE 4YPE IMPORTANT Finished hoistway dimensions must include the drywall Determine the fire rating of the hoistway the type and layers of sheet rock and build only off the final installation shop drawings specific to your project ...

Страница 7: ...nd wiring are provided and installed by others The light must be guarded to prevent accidental breakage of contact with the hot bulb The switch light wiring and guard are provided and installed by others A convenience outlet of 115V single phase 15 amp with G F I shall be located next to the light switch in the machine room provided and installed by others A telephone line circuit is to be provide...

Страница 8: ...8 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Machine room dimensions 5 ...

Страница 9: ...28 711 mm Depth 17 432 mm Minimum required clearance 39 37 1000 mm Valve and manual lowering handle location Inside tank Rupture valve test T fitting factory installed Tank to controller wiring Quick connect valve and motor wiring Controller layout Relay board Keyed lock to tank Yes Machine room required No with local jurisdiction approval Tank capacity gal ltr 15 16 5 gal 57 63 ltr Maximum dry we...

Страница 10: ... CONSULT YOUR 3AVARIA REPRESENTATIVE FOR EXACT LOCATION NTERMEDIATE RAIL BRACKET 2 IN MM INTERVALS ABOVE BOTTOM BRACKET OTTOM RAIL BRACKET 2 IN MM ABOVE PIT FLOOR IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawing refer to Appendix A instead ...

Страница 11: ...finity HD Planning Guide Elevation view Infinity HD 8 4OP RAIL BRACKET AT TOP OF HOISTWAY CONSULT YOUR 3AVARIA REPRESENTATIVE FOR EXACT LOCATION NTERMEDIATE RAIL BRACKET IN MM INTERVALS ABOVE BOTTOM BRACKET OTTOM RAIL BRACKET IN MM ABOVE PIT FLOOR ...

Страница 12: ...5 Plan view Infinity 36 x 48 type 1 left hand 9 Plan view Infinity 36 x 48 type 1 right hand 10 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 13: ...nning Guide Plan view Infinity 36 x 48 type 2 11 Plan view Infinity 36 x 48 type 3 12 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 14: ...24 m09 2015 Plan view Infinity 36 x 48 type 4 13 Plan view Infinity 36 x 48 type 5 14 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 15: ...e Plan view Infinity 36 x 54 type 1 left hand 15 Plan view Infinity 36 x 54 type 1 right hand 16 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 16: ...24 m09 2015 Plan view Infinity 36 x 54 type 2 17 Plan view Infinity 36 x 54 type 3 18 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 17: ...nning Guide Plan view Infinity 36 x 54 type 4 19 Plan view Infinity 36 x 54 type 5 20 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 18: ...5 Plan view Infinity 36 x 60 type 1 left hand 21 Plan view Infinity 36 x 60 type 1 right hand 22 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 19: ...nning Guide Plan view Infinity 36 x 60 type 2 23 Plan view Infinity 36 x 60 type 3 24 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 20: ...24 m09 2015 Plan view Infinity 36 x 60 type 4 25 Plan view Infinity 36 x 60 type 5 26 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 21: ...e Plan view Infinity 40 x 54 type 1 left hand 27 Plan view Infinity 40 x 54 type 1 right hand 28 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 22: ...24 m09 2015 Plan view Infinity 40 x 54 type 2 29 Plan view Infinity 40 x 54 type 3 30 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 23: ...nning Guide Plan view Infinity 40 x 54 type 4 31 Plan view Infinity 40 x 54 type 5 32 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Страница 24: ...24 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity HD 48 x 60 type 1 left hand 33 ...

Страница 25: ...25 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Plan view Infinity HD 48 x 60 type 1 right hand 34 ...

Страница 26: ...26 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity HD 48 x 60 type 2 35 ...

Страница 27: ...27 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Plan view Infinity HD 48 x 60 type 3 36 ...

Страница 28: ...28 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity HD 48 x 60 type 4 37 ...

Страница 29: ...29 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Plan view Infinity HD 48 x 60 type 5 left hand gate stack door swing 38 ...

Страница 30: ...30 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity HD 48 x 60 type 5 right hand gate stack door swing 39 ...

Страница 31: ...aria com select the architects and builders tab at the top of the page and then select Doors and Gates from the menu on the left hand side of the page The link is as follows http www savaria com architects drawings doors gates index php Recommendation We recommend installation of a solid door as a hollow door may be too flexible and cause potential lock issues ...

Страница 32: ...nfinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Loads on building and rail dimensions 41 Rail bracket dimensions Infinity Support wall orientation Rails Rail bracket dimensions Infinity HD ...

Страница 33: ...ttom of the slab in two traverse directions and at a spacing of 12 305 mm Hoistway pit floor to support a load including impact of 5 6 kips 5600 lb 24 9 kN for Infinity or 8 22 kips 8220 lb 36 6 kN for Infinity HD Minimum overhead clearance of 92 2337 mm for 80 2032 mm cab 96 2438 mm for 84 cab and 108 2743 mm for 96 cab Minimum pit depth of 8 203 mm for Infinity and 12 305 mm for Infinity HD Hois...

Страница 34: ...34 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Masonry construction sectional view 43 ...

Страница 35: ...35 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Masonry construction plan view 44 ...

Страница 36: ...36 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Wood construction sectional view 45 For Reference Only ...

Страница 37: ...37 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Wood construction plan view 46 ...

Страница 38: ...38 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Suggested wall configuration for wood construction sheet 1 47 Refer to previous section Loads on building for rail forces R1 R2 R3 ...

Страница 39: ...39 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Suggested wall configuration for wood construction sheet 2 48 ...

Страница 40: ...re applied to the wall from the floor or roof system and modify member sizes or connections as required by their analysis G4 Do not scale the drawings G5 See the lift installation shop drawings for service loads including dynamic effects which are Horizontal load parallel to the wall 194 lbf 0 86 kN for Infinity 251 lbf 1 12 kN for Infinity HD Horizontal load perpendicular to the wall 304 lbf 1 35...

Страница 41: ... o Return walls at entrances must be built in by others after entrance assemblies are in place Entrance assembly must be securely fastened to walls by elevator contractor o Fascia panel below upper level entrance where required Fascia panel must be fastened to a solid wall and be perpendicular to the floor and walls Hoistway fascia is not self supporting for long continuous runs void of entrances ...

Страница 42: ...ual 3 20 amp 3 20 amp 3 20 amp Cab Lighting 1 Pole Solid Neutral 120V 1 PH GP 111N 86211 CFN 211 Required Type D Fuse Buss type T or equal 1 15 amp 1 15 amp 1 15 amp Disconnect Switch Types Accessories Cutler Hammer Federal Pioneer Siemens 1 Phase 5 H P Pump Unit 2 Pole 240V 1 PH 1HD221N 1322SN ID321 Required Auxiliary Contact DS16CP E1K 1AEV W94 MSSAK 116 Required Type D Fuse Buss type FRN or equ...

Страница 43: ...43 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide COP dimensions 51 ...

Страница 44: ...44 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Hall call dimensions 52 ...

Страница 45: ...D Planning Guide Appendix A Infinity with Auto Slim Doors This appendix provides elevation and plan view drawings for the various Infinity cab types with Auto Slim Doors Drawings for the auto slim doors entrance assembly are provided on the next two pages ...

Страница 46: ...46 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Auto slim doors entrance assembly CO 2100 ...

Страница 47: ...47 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 1L with auto slim doors ...

Страница 48: ...48 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 1L with auto slim doors ...

Страница 49: ...49 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 1R with auto slim doors ...

Страница 50: ...50 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 1R with auto slim doors ...

Страница 51: ...51 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 2 with auto slim doors ...

Страница 52: ...52 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 2 with auto slim doors ...

Страница 53: ...53 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 3 with auto slim doors ...

Страница 54: ...54 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 3 with auto slim doors ...

Страница 55: ...55 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 4 with auto slim doors ...

Страница 56: ...56 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 4 with auto slim doors ...

Страница 57: ...57 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 5 with auto slim doors ...

Страница 58: ...58 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 5 with auto slim doors ...

Страница 59: ......

Страница 60: ...2 Walker Drive Brampton ON Canada L6T 5E1 Phone 905 791 5555 Fax 905 791 2222 Sales 800 661 5112 www savaria com ...

Отзывы: