background image

GPIO and Relay Wiring

General Purpose Input/Outputs (GPIO) are binary I/O ports used on 
Savant® controllers used to trigger an action within the system. Events 
can be the control of a device, such as turning on an amplifier (output) 
or detecting a state change for a device (input) to perform a workflow.  
The left 3 pins of the supplied 6-pin Screw Down Plug-in Connector are 
used for GPIO connections. 

Relays are used when a contact closure (normally open or normally 
closed) is needed to activate a device. An action such as raising or 
lowering shades, opening or closing a gate, or sending control signals 
to an HVAC system are a few examples. The right 3 pins of the supplied 
6-pin Screw Down Plug-in Connector are used for Relay connections. 

GPIO Pull Down Resistor (PD) Usage

GPIO pins are configured as inputs and are pulled high to 12V while the 
host is booting up. To make the GPIO signal low during a host reboot 
and/or a power cycle, attach the GPIO 1 pin to the PD pin. The PD pin is 
a 1K ohm pull down resistor (to signal ground)

 

which keeps the GPIO 

output below 0.8V during processor boot times.

Making Connections

1.

Remove Power if power is applied.

2.

Pull to remove the terminal block from the rear of the controller.

3.

With a small flat bladed screwdriver, turn the screws on the top of 
connector counterclockwise until the silver crimps in the front of the 
connector opens enough to slide the wires into the square slots.

4.

Insert one of the stripped wires from the devices being controlled 
into its respective slot in the connector. Refer to the diagrams above.

5.

Turn the screw clockwise until the screw tightens around the wire. 
Tug on the wire a bit to verify it is installed securely. Do not allow 
more than 1/2 inch of stripped wire exit from the rear of the 
connector.

6.

Repeat for each wire till all wires are installed. 

7.

Plug terminal blocks back into rear of the controller.

8.

Reapply power.

Additional Documentation

Additional Documentation is available on the 

Savant Customer 

Community

.

SmartControl 2 (SSC-W002G) Deployment Guide - 009-1273-xx

Relay and General Purpose Input/Output Profiles: Application Note

Savant Controllers Family video in the Savant University pages

Regulatory

The following statements are applicable to the Savant SmartControl 2 
SSC-W002G controller.

FCC Regulations:

15.19. These devices comply with part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) These devices may not 
cause harmful interference, and (2) these devices must accept any 
interference received, including interferences that may cause 
undesired operation.
15.21. The changes or modifications not expressly approved by the 
party responsible for compliance could void the user's authority to 
operate the equipment.
15.105. This equipment has been tested and found to comply with the 
limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a residential 
environment. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications, 
However there is no guarantee that interference will not occur in a 
particular installation, If this equipment does cause harmful 
interference to radio or television reception, which can be determined 
by turning the equipment o

 and on, the user is encouraged to try to 

correct the interference by one or more of the following measures: 
- Reorient or relocate the receiving circuit di

erent from that to which 

receiver is connected. 
- Increase the separation between the equipment and the receiver.
- Consult the dealer or experienced radio/TV technician for help. 

IC Regulations:

RSS-Gen 7.1.3.  These devices comply with Industry Canada license-
exempt RSS standard(s). Operation is subject to the following two 
conditions: (1) These devices may not cause interference, and (2) 
These devices must accept any interference, including interference 
that may cause undesired operation of the device. 
RSS-21- Annexe 9: A 9.4. Le présent appareil est conforme aux CNR 
d'Industrie Canada applicables aux appareils radio exempts de licence. 
L'exploitation est autorisée aux deux conditions suivantes: (1) 
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de 
l'appareil doit accepter tout brouillage radioélectrique subi, même si 
le brouillage est susceptible d'en compromettre le fonctionnement.

SSC-W002G-00  |  009-1257-01  |  160210

45 Perseverance Way, Hyannis, MA 02601

Copyright © 2016 Savant Systems, LLC

2

of

 2

Savant.com

  |  508.683.2500

Отзывы: