Savant Power System Wiring and Installation Deployment Guide
Copyright 2022 Savant Systems, Inc
009-2222-02 | 080122
- 9 -
4. Power Panel Installation
A Savant Power Panel is a breaker panel with one or more Power Modules installed. A
Power Module
is a load monitoring and controlling device installed
into electrical panels as easily as a circuit breaker. Power Modules communicate with the Savant Power System through the
Panel Bridge Controller
via
Bluetooth. Review the wiring diagrams below and confirm that all proper physical installation has been completed before proceeding.
IMPORTANT NOTE!:
DO NOT CONNECT ANY
mission-critical loads such as medical devices to
ANY
Power Module.
4.1. 120V 20A Dual Relay Power Modules (GPM-QP2R20120-21)
ARC Fault Breakers
IMPORTANT NOTES!
– The 120V 20A Dual Relay Power Modules switches on
and off loads A and B.
– The main electrical panel contains ARC fault
breakers. See the next page for the standard non-
ARC fault breaker diagram.
– The diagram shows connections for both a
plug-on
neutral
and
pigtail neutral wire
120V 20A Dual Relay
Power Modules. Make connections according to the
type of breaker being installed.
– Neutral and ground wires on both load centers must
be common.
Ground Bar
The neutral on an ARC
fault breaker can be either
a pigtail wire, or plug-on
neutral bus bar clip.
Connect a Gnd
wire to each load
Load A
BREAKER
BREAKER
BREAKER
INPUT
OUTPUT
OUTPUT
B
A
B
A
INPUT
CIRCUIT PO
WER
ON
A
U
TO
PAIR
A
B
20A DU
AL RELA
Y
INPUT
OUTPUT
OUTPUT
B
A
B
A
INPUT
CIRCUIT PO
WER
ON
A
U
TO
PAIR
A
B
20A DU
AL RELA
Y
Load B