background image

SAVANNAH STOKER v3 INSTRUCTION MANUAL 

2015.01 Copyright © Sound Solutions, LLC.  All Rights Reserved.  Find us on Facebook.com/SavannahStoker , Pelletheads.com and LetsTalkBBQ.com                                                              

3

                  

2. Quick Start Guide 

3. The Front Panel 

 

Yep, instead of reading the rest of the manual you’re in a hurry 

to  fire  up  the  smoker  and  see  what  the  Savannah  Stoker  can  do. 
Right?  Well,  for  everyone  just  like  you  this  Quick  Start  Guide  was 
prepared. So, what are you waiting for!  Time to smoke something 
even it’s just air.  

(air=empty grill) 

   

 
2.1

 

Start-up. 

NOTE:

 Refer to your smoker’s owner manual for recommended start-

up and safety procedures. Always start with a clean smoker for best 
results. 

 

1)

 

Plug  the  smoker  to  a  GFCI  protected  AC  outlet,  it’s  a  safety 
thing.  The  Stand-by  indicator  will  illuminate  RED  indicating 
power is present at the controller.  

2)

 

Press  the  Power  KEY

.  The  Stand-by  indicator  will  go  OFF. 

Both  displays  on  the  controller  will  flash,  then  the  top  display 
(PV)  will  show  the  current  temperature  inside  the  cooking 
chamber.  The  bottom  display  (SV)  is  the  desired  cooking 
temperature.  You  can  read  more  about  (PV)  &  (SV)  in  the 
column to the right, ….. later right? 

3)

 

The AUG and IGN indicator lights will be ON.  

4)

 

After several minutes the pellets will start to smolder and whitish-
gray smoke will billow out then change color to that thin blueish 
smoke. You’ve seen this before.   

 

5)

 

When the cooking chamber reaches 130°+ the IGN indicator will 
go OFF, so did the Igniter. 

 

6)

 

Notice the AUG indicator cycling ON and OFF? If not now, it will, 
just keep watching. ON, the auger running. OFF, it’s not. 

 

7)

 

When the smoker has heated up, cook something. It’s better to 
cook food than air. Besides, while you’re just sitting and watching 
the controller’s displays and smelling the smoke for the next hour 
you could cook some sausage for tomorrow’s breakfast. 

 

 

2.2

 

Setting the Cooking/Smoking Temperature (SV). 

Recommended  start-up  temperature  is  225°  to  preheat  the  grill,  but 
any start-up temperature can be set between 160° - 550°F in one (1°) 
degree increments. To change the Setpoint Value (SV) press/release 
the ▼ or ▲ KEY. The decimal point on the lower right corner of the 
display will start to flash. Press the ▼ or ▲ KEY to change SV until 
the  desired  temperature  is  displayed.  The  decimal  point  will  stop 
flashing  after  no  KEY  is  pressed  for  3  seconds.  You  can  press  the 

A/M KEY

 to move the flashing decimal point to the desired digit that 

needs to change. Then press the ▼ or ▲ KEY to change SV starting 
from that digit.

 

 

 

2.3

 

Shut down.

 

1)

 

Set the temperature (SV) to 225° or your future desired start-up 
temperature. 

2)

 

If  you  changed  the  FAN  speed  to  medium  or  low,  reset  the 

FanS

 value to 3. (If you changed the speed you have read most 

of the manual.)   

3)

 

Press  the  POWER  KEY

.  The  top  display  will  flash  “HOT” 

and  the  FAN  indicator  will  blink  until  the  cooking  chamber 
temperature drops below 120° (the value of 

Fant

4)

 

The controller will power-off and the Stand-by indicator will    
illuminate RED indicating power is present at the controller.

 

5)

 

Disconnect the power source.

 

6)

 

Store the grill & cover. The controller should be protected from 
the elements. Water damage is not covered under the warranty.

 

 
3.1 Understanding the Front Panel.   

The numbers in the circle before each feature refers to Figure 2.

   

 

  

Stand by indicator:

 Light is on when the controller is connected to 

a power source but not running. When the controller is running the 
light will go off and the displays will be on. 

②  

PV display:

  The temperature inside the cooking chamber; 

commonly  referred to as Process Variable or Process Value (PV). 

③ 

SV display:

 When in normal operation mode this is the target 

temperature; it is commonly referred to as Setpoint Value (SV). 
When in display mode 2, it indicates the mode the controller is in 
(Automatic or Manual) and the output value (%).  

④ 

FAN indicator

:  Light blinks when in “Cool Down”. 

 

⑤ 

IGN indicator:

   Light is on when the IGNITER is on. 

⑥ 

A/M indicator:

  Light is on when the controller is in MANUAL 

MODE. 

  

AUG indicator:

  Light is on anytime the AUGER is running. 

⑧ 

A/M KEY:

 Automatic/Manual function KEY; Data shift KEY   

  Decrement KEY

 

: Decreases numeric value of the SV display. 

⑩ 

Increment   KEY

 

:  Increases numeric value of the SV display. 

⑪  

SET KEY:

 

Pressed momentarily, the controller switches the lower 

display (SV) between setpoint value and percentage of output. 
When pressed and held for two seconds the controller will enter the 
parameter setting mode. 

⑫  

AUG KEY

: When engaged, the auger runs continuously.  

⑬ 

Power KEY

: When the controller is off and the Stand by 

indicator is RED, press the Power KEY to start the controller. When 
the controller is ON, pressing the Power KEY will start the “Cool 
Down” cycle. See 4.1. 

 

 

 

4

5

11

8

2

3

1

6
7

9

10

12
13

 

 

Figure 2. Front Panel

Содержание STOKER v3

Страница 1: ...40VAC 3A Igniter Output Zero crossing SSR 100 240VAC 10A Power supply 100 240VAC 50 60Hz Power consumption 300 Watts at startup 60 Watts normal operation Ambient temperature 0 50 C 32 122 F Fuse 5x20m...

Страница 2: ...oller to the pellet hopper saving the screws for use later 2 Gently pull the controller away from the hopper while sliding it slightly to the right Rotate the left side toward you so the circuit board...

Страница 3: ...point will stop flashing after no KEY is pressed for 3 seconds You can press the A M KEY to move the flashing decimal point to the desired digit that needs to change Then press the or KEY to change SV...

Страница 4: ...ller is in the Automatic Control Mode Pressing the A M KEY will switch the controller to Manual Control Mode When in Manual Control Mode the first digit to the left will change to an M to indicate Man...

Страница 5: ...Ys will lower or raise the auger runtime Note Manual mode will be running the last output value when the controller was in Automatic Mode The runtime cannot be set lower than the OutL parameter value...

Страница 6: ...acteristics of your barbecue Chart and save your cook data Set alarms on your computer Ramp temperatures up down by time or food temperature and more The author posts on the Virtual Weber Bulletin Boa...

Страница 7: ...note the controller uses an enhanced version of PID control algorithms Tuning of the controller is different than traditional PID controllers The parameters are explained below Before adjusting any o...

Страница 8: ...second cycle time or 3 4 seconds OutH is the maximum of the cycle time the auger will run Default is 100 The high limit is used to help reduce temperature overshoots that will occur at start up after...

Отзывы: