Application
8.1
Check before starting the measurement / test
•
Wiring, switching on Display flashes 5 times
•
Test the movement without the test piece, manually actuating the limit
switches to test their function.
•
Test of the automatic movement. Press the Manual/Auto Mode button, Auto
Mode indicator lights up. Set cycles (avoid setting "1"), start test run with Up or
Down button. At the end of the cycles, the test bench stops and emits an
alarm tone 3 times, test finished.
8.2
Speed setting
The speed can be adjusted continuously up to the maximum. The set speed can be
read off the display.
8.3
Presettable cycles
A number of cycles can be preset on the test bench. The preset value is displayed in
the lower area. It can be set
with the keys Counter
, Counter
and Select
counter position. The "run" number is displayed in the upper area. The counter can
be
reset with the Zero key.
8.4
RS 232 connection
The test stand has two 9-pin connectors to connect a force gauge and one connector
for communication with the PC. The test stand can be operated with SAUTER AFH
software. This allows the motion control and number of cycles to be set directly on
the PC. The software can be used to evaluate the data in terms of force-time or
force-displacement. The test stand can be controlled at the connection for the force
measuring device using an FH series force measuring device to prevent overload
(using the Stop parameter on the FH series force measuring device).
8.5
Limit switch
In manual mode, movement stops when the limit switches are reached. In Automatic
mode, movement stops at the Perimeter Switch for about 5 seconds and then
continues in the opposite direction. In order to ensure that the test/examinations run
smoothly, you should ensure that you align the boundary rings very precisely so that
the test object or test equipment is not destroyed if the path is too long/short.
Содержание TVM 10kN120N
Страница 12: ...12 TVM N BA e 2020 11 Technical drawings...