sauter TVM 10kN120N Скачать руководство пользователя страница 6

 

 

TVM-N-BA-e-2020 

Control panel 

 

Function 

Declaration 

Main switch: 

Switching the test bench on / off 

Direction switch OPEN: 

Lower slide moves upwards (as 

long as is pressed) 

Direction button AB: 

Lower slide moves downwards (as 

long as is pressed) 

Stop button: 

In Auto Mode the movement is 

stopped 

Speed control knob: 

Regulation of the lifting speed 

Manual / Auto Mode: 

Choice between manual or 

automatic movement 

Display of preset cycles: 

With the help of the counters 

counters 

and selection of 

counter position 

a number can 

be preset, how many cycles are to 

be run 

Display of driven 

Cycles: 

The number of cycles completed is 

displayed here 

Reset button: 

Zeroing of the driven cycles

 

 
The movement of the test bench is defined by the lower and upper limiting ring. 
These limiting rings must be adjusted for each test.  

Содержание TVM 10kN120N

Страница 1: ...72336 Balingen e mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction manual motorized test bench SAUTER TVM N Version 2 0 01 2020 GB TVM N BA e 202...

Страница 2: ...Scope of delivery 3 3 Weight and dimensions 3 4 Check before use 3 5 Possible applications 4 6 Technical data 5 7 Control panel 6 8 Application 7 8 1 Check before starting the measurement test 7 8 2 S...

Страница 3: ...SAUTER TVM Power cord Operating instructions Accessories depending on model 3 Weight and dimensions Test bench TVM 5000N230N TVM 5000N230NL TVM 10KN120N TVM 20KN120N TVM 30KN70N Dimension LxWxH 410x26...

Страница 4: ...the setting options of the FH force gauge can be used for example to protect the test stand from overload with the STOP value Choose the right test stand with regard to the maximum force you require A...

Страница 5: ...00 N 30 000N Speed range 10 230 mm min 10 230 mm min 30 120 mm min 30 120 mm min 5 70 mm min Speed accuracy 1 100 mm min 2 mm min 100 mm min 10 Maximum travel distance 200mm Maximum number of cycles 1...

Страница 6: ...ol knob Regulation of the lifting speed Manual Auto Mode Choice between manual or automatic movement Display of preset cycles With the help of the counters counters and selection of counter position a...

Страница 7: ...The counter can be reset with the Zero key 8 4 RS 232 connection The test stand has two 9 pin connectors to connect a force gauge and one connector for communication with the PC The test stand can be...

Страница 8: ...trained and experienced personnel In particular it should be avoided that forces are applied to the measuring instrument by the test bench which exceed the maximum load Max of the test bench or measur...

Страница 9: ...ere as an example with a FH 500 10 2 with external load cell TVM 5000N230N NL and TVM 10KN120N Mounting bracket AFM 41 with 4x M6x35 black with washer and spring washer on crossbar Screws The external...

Страница 10: ...AFM 41 mounting bracket with an M12x80 screw for TVM 20KN and TVM 30KN included in the scope of delivery Here as an example with a FH 20K 10 4 Wiring of the test bench model independent The force gau...

Страница 11: ...tension cable to PC 10 5 Cabling TVM with a force measuring and length measuring device Wire the force gauge wiring as described in previous points of section 10 Connect the linear encoder to the PC v...

Страница 12: ...12 TVM N BA e 2020 11 Technical drawings...

Страница 13: ...H mm I mm TVM 5000N230N 250x380x410 635 32 220 185 400 165 TVM 5000N230NL 250x380x410 1120 32 220 190 400 165 TVM 10kN120N 250x380x410 1120 32 220 180 400 165 TVM 20kN120N 295x545x480 1135 35 295 200...