5
3 Operating Panel Description
3-1
Measuring probe
3-2
Display
3-3
"ZERO" button
3-4
"Plus" button
3-5
"Minus" button
3-6
"ON/OFF" (multipurpose) button
3-7
"µm/mil" switch button (keyboard shortcut)
3-8
Battery compartment/cover — back
3-9
Port of RS-232C interfaces
3-10
"S/C" (single/continuous) measurement mode button
4 Measurement Procedure
4.1 Insert the F- or N-type measuring probe, depending on the measured object.
4.2 Switch the instrument on, pressing "ON/OFF" 3-6. The display 3-2 will display "0".
The instrument TE can recognize the measuring probe (sensor) while displaying the
relevant symbol, i.e.: "Fe" (= F) for ferrous metals or "NFe" (= N) — for non-ferrous
metals.
4.3 Place the measuring probe 3-1 on the measured layer. The layer thickness can
be read on the display. The measurement result can be adjusted by pressing "Plus"
3-4 or "Minus" 3-5 key. Remember the measuring probe should not be situated in the
immediate vicinity of the measured coating or calibration plate.
4.4 To carry out another measurement, raise the measuring probe 3-1 by more than
1 cm, until '0" is displayed again, and repeat step 4.3.
3-1
3-10
3-7
3-8
3-9
3-6
3-5
3-4
3-2
3-3
here: TE 1250-0.1FN model