Instruction Manual 

FK Tensio 

 

FK_T-BA-e-1110 

 

 

 

9. Warning 

 
9.1 Intended  use 
 
The instrument you have acquired serves to determine the 
measuring value of the material to be measured. It is 
intended to be used as a “non-automatic“  instrument, i.e. 
the material to be measured is manually and carefully 
attached at the instrument. The measuring value can be 
read off after a stable measuring value has been obtained. 
 
9.2 Inappropriate use 
 
Do not use the instrument for dynamic measuring. In the 
event that small quantities are removed or added to the 
material to be measured, 
incorrect measuring results can be displayed due to the 
“stability compensation“ in the instrument. (Example: Slow 
draining off of liquid from a container suspended from the 
instrument). Do not attach a continuous load. This can 
damage the measuring unit as well as the parts, 
relevant to safety. 
 
Prevent jolts, torsion and oscillation (e.g. by appending 
slopingly) of all kinds. Be sure to prevent overloading the 
instrument in excess of the stated maximum load (max.), 
minus any tare weight that may possibly exist. This could 
damage the instrument (risk of breakage). 
 
 
 
Important: 

• Always make sure that there are no people or materials 
below the load that could be injured or damaged! 
• The instrument is not suitable for measuring people. Do 
not use as baby scales! 
• The instrument does not comply with the medical product 
law (MPG). 
Never operate the instrument in hazardous locations. The 
series design is not explosion-proof. Structural alterations 
may not be 
made to the instrument. This can lead to incorrect 
measuring results, faults concerning safety regulations as 
well as to destruction 
of the instrument. The instrument may only be used in 
compliance with the described guidelines. Varying areas of 
application/ 
planned use must be approved by SAUTER in writing. 
 
9.3 Guarantee 
 
The guarantee is not valid following 
• non- observation of our guidelines in the operating 
instructions 
 
• use outside the described applications 
• alteration to or opening of the device 
• mechanical damage and damage caused by media,  
liquids 
• natural wear and tear 
• inappropriate erection or electric installation 
• overloading of the measuring equipment 
 
9.4 Monitoring the test substances 
 
The metrology features of the instrument and any possible 
available adjusting weight must be checked at regular 
intervals within the scope of quality assurance. For this 
purpose, the answerable user must define a suitable 
interval as well as the nature and scope of this check. 
Information is available on 
the home page (

www.KERN-sohn.com

) with regard to the 

monitoring of instrument test substances and the test 
weights required for this. Test weights and instruments can 
be adjusted quickly and at a reasonable price in KERN’s 
accredited DKD calibration laboratory (return to national 
normal). 
 
9.5. Fundamental safety information 
 
Do not use the hanging instrument to transport loads. 
Prevent jolts, torsion and oscillation (e.g. by appending 
slopingly) of all kinds. 
Never use the hanging instrument over the maximum 
permitted weight (!! Danger of breaking !!). 
Always make sure that there are no living beings or 
materials below the load that could be injured or damaged. 
The hanging electronic instruments from the SAUTER 
instrument are only suitable for hand-held use or use in a 
test stand. 

Содержание FK Tensio

Страница 1: ...cell is inside the housing Table of contents 1 Included in delivery 2 Working conditions 3 Electrical power supply 4 Technical data 5 Operation 6 Backside fixing on a test stand 7 Adjusting procedure 8 Declaration of conformity 1 Included in delivery SAUTER FK Power cable Standard attachments as shown below Terms Track continuous measurement Peak Capture of the maximum value The measuring device o...

Страница 2: ...t unit N kg lb ou ZERO Zeros the measuring result Tara function Cleans the peak value in Peak mode c Display Return When the instrument itself is turned that the head faces down the display returns automatically d Measurement Track Modus Display 1 shows the continuous force in a defined direction 3 To zero the display press ZERO e Peak Hold Function Peak Mode Please press MAX 6 Backside Fixture to...

Страница 3: ...Structural alterations may not be made to the instrument This can lead to incorrect measuring results faults concerning safety regulations as well as to destruction of the instrument The instrument may only be used in compliance with the described guidelines Varying areas of application planned use must be approved by SAUTER in writing 9 3 Guarantee The guarantee is not valid following non observa...

Страница 4: ...110 4 They are not suitable for hanging from a mechanical hook e g a crane hook 9 5 1 Observe the information in the operating instructions please read the operating instructions carefully before erecting and commissioning even if you already have experience with SAUTER instruments 9 5 2 Staff training The device may only be operated and looked after by trained members of staff ...

Отзывы: