7  Warning 

 
Force measurements which have been  performed in an incorrect  way, can lead to 
serious injuries  of  living beings  and damage of objects. Therefore trained staff may 
practice them only. 
Be sure to prevent overloading the instrument (over the maximum permitted weight) 
in excess of the stated maximum load (max.), minus any tare weight that may possi-
bly exist. Do not use the hanging instrument to transport loads. 
Prevent jolts, torsion and oscillation (e.g. by suspending  loads aslope) of all kinds, 
because there is a risk of breakage and in all cases there will be a lack of measure-
ment accuracy.  
 

 

 
 

Inappropriate use 

Do not use the instrument for medical measurements. In the case that small quanti-
ties are removed or added to the material to be measured, incorrect measuring re-
sults can be displayed, due to the “stability compensation“ in the instrument (such as 
slowly draining off of liquid from a container suspended from the instrument). Do not 
attach a continuous load. This can damage the measuring unit as well as the parts, 
relevant to safety. 
 

Overload 

Be sure to prevent overloading the instrument in excess of the stated maximum load 
(max.), minus any tare weight that may possibly exist. This could damage the instru-
ment (risk of breakage). 

Attention: 

- Always make sure that there are no people or materials below the load that could 
be injured or damaged! 
- The instrument is not suitable for measuring people. Do not use it as a baby scale! 
- The instrument does not comply with the medical product law (MPG). 
- Never operate the instrument in hazardous locations. The series design is not ex-  
  plosion-proof. 
- Structural alterations may not be exerted on the instrument. This can lead to incor-
rect measuring results, faults concerning safety regulations as well as to destruction 
of the instrument.  
- The instrument may only be used in compliance with the described guidelines.  
- Varying ranges of applications or planned use must be approved by SAUTER in  
  writing. 
 

Содержание FA

Страница 1: ...mbH Ziegelei 1 D 72336 Balingen E Mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Mechanical Force Gauge SAUTER FA Version 1 3 11 2016 GB FA BA e 1613 ...

Страница 2: ...e of SAUTER We hope you are pleased with your high quality force gauge with its functional range If you have any queries wishes or helpful suggestions do not hesitate to call our service number Summarize 1 Scope of delivery 3 2 Working Conditions 3 3 Technical Data 4 4 Measurement 4 5 Adaptation to Test Stands 4 6 Drawings 4 7 Warning 5 ...

Страница 3: ... attachments as shown beside Explanation Track continuous measuring Peak Capture of the Maximum value 2 Working Conditions Working temperature 10 C to 30 C Humidity 15 up to 80 Turnable display Drag indicator Switch Track Peak Force Sensor Direction Push Direction Pull ...

Страница 4: ...e pressing and turning the knob simultaneously to get the right position Zero Setting In Peak position by once pressing the shift key Tare Function Zero setting by turning the indicator correspondingly Advice When the force gauge is not in use leave it in Peak position this will extend life of the spring measurement system 5 Adaptation to Test Stands Onto all SAUTER test stands with four M3 screws...

Страница 5: ...wly draining off of liquid from a container suspended from the instrument Do not attach a continuous load This can damage the measuring unit as well as the parts relevant to safety Overload Be sure to prevent overloading the instrument in excess of the stated maximum load max minus any tare weight that may possibly exist This could damage the instru ment risk of breakage Attention Always make sure...

Страница 6: ...ht must be checked at regular intervals within the scope of quality assurance For this purpose the responsible user must define a suitable interval as well as the nature and scope of this inspection Information is available on SAUTER home page www sauter eu concerning the monitoring of instrument test substances and the test weights required for this Test weights and instruments can be adjusted qu...

Отзывы: