sauter FA Скачать руководство пользователя страница 3

FA-BA-e-1613 

 

 

1  Scope of delivery 

 

-  SAUTER FA                                                              
-  Transport case                                                 

-  Standard attachments, as shown beside           

 

 

 
                                                                                                             

                          

 

 
 
Explanation: 
Track  

= continuous measuring 

Peak 

= Capture of the Maximum value 

2  Working Conditions 

 
Working temperature: 10°C to 30°C 
Humidity: 15% up to 80%  

Turnable display  

Drag 
indicator 

Switch  
Track / Peak 

Force Sensor 

Direction  
(Push) 

Direction 
(Pull) 

 

Содержание FA

Страница 1: ...mbH Ziegelei 1 D 72336 Balingen E Mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Mechanical Force Gauge SAUTER FA Version 1 3 11 2016 GB FA BA e 1613 ...

Страница 2: ...e of SAUTER We hope you are pleased with your high quality force gauge with its functional range If you have any queries wishes or helpful suggestions do not hesitate to call our service number Summarize 1 Scope of delivery 3 2 Working Conditions 3 3 Technical Data 4 4 Measurement 4 5 Adaptation to Test Stands 4 6 Drawings 4 7 Warning 5 ...

Страница 3: ... attachments as shown beside Explanation Track continuous measuring Peak Capture of the Maximum value 2 Working Conditions Working temperature 10 C to 30 C Humidity 15 up to 80 Turnable display Drag indicator Switch Track Peak Force Sensor Direction Push Direction Pull ...

Страница 4: ...e pressing and turning the knob simultaneously to get the right position Zero Setting In Peak position by once pressing the shift key Tare Function Zero setting by turning the indicator correspondingly Advice When the force gauge is not in use leave it in Peak position this will extend life of the spring measurement system 5 Adaptation to Test Stands Onto all SAUTER test stands with four M3 screws...

Страница 5: ...wly draining off of liquid from a container suspended from the instrument Do not attach a continuous load This can damage the measuring unit as well as the parts relevant to safety Overload Be sure to prevent overloading the instrument in excess of the stated maximum load max minus any tare weight that may possibly exist This could damage the instru ment risk of breakage Attention Always make sure...

Страница 6: ...ht must be checked at regular intervals within the scope of quality assurance For this purpose the responsible user must define a suitable interval as well as the nature and scope of this inspection Information is available on SAUTER home page www sauter eu concerning the monitoring of instrument test substances and the test weights required for this Test weights and instruments can be adjusted qu...

Отзывы: