background image

2

EGQ220F931

D G F I

Maßzeichnung

 

Dimensional drawing 

 

Plan coté 
Disegno quotato

 

TK: 

ø60

85

85

27.2

Zum Öffnen des Gehäuses einen Schraubendreher (2,0) in die Nut 
mittig ansetzen, nach unten drücken und den  Bodenrahmen etwas 
anheben. Den Deckel nach vorne ziehen und halten.

To open the housing, set a screwdriver (2.0) in the groove at  centre, 
press down, and lift up the bottom frame slightly. Pull top cover for-
ward and hold it.

Pour ouvrir le boîtier placer le tournevis (2,0) au centre de l’encoche, 
pousser vers le bas et soulever légèrement le cadre inférieur. Tirer 
le couvercle vers l’avant et le maintenir.

Per aprire l'involucro, utilizzare un cacciavite a taglio (2,0) nel solco al 
centro, premere verso il basso e sollevare il coperchio leggermente. 
Tirare poi il coperchio ed estrarlo.

Gehäuse 

 

Housing

   

Boîtier   
Involucro

EGQ220F931

Содержание EGQ220F931

Страница 1: ...d instruction Sonde d ambiance CO2 auto calibrant avec sortie active I Istruzioni per l uso e per il montaggio Sonda di CO2 per ambiente calibrazione automatica con uscita attiva CARTONS ET EMBALLAGE...

Страница 2: ...n the groove at centre press down and lift up the bottom frame slightly Pull top cover for ward and hold it Pour ouvrir le bo tier placer le tournevis 2 0 au centre de l encoche pousser vers le bas et...

Страница 3: ...C typisch Peakstrom 200 mA Sensor optischer NDIR Sensor nicht dispersive Infrarot Technologie mit manueller Kalibrierung ber Zero Taster mit automatischer Kalibrierung fest eingestellt Messbereich 0 2...

Страница 4: ...hrt die Kalibrierung automatisch durch Es reicht aus in regelm igen Abst nden die Fenster zu ffnen bzw die L ftungsanlage auf Au enluft einzustellen und dabei alle CO2 erzeugenden Vorg nge die die Umg...

Страница 5: ...g ge messen Wird dieses Ger t mit DC Versorgungsspannung betrieben ist der Betriebsspannungseingang UB f r 15 36 V DC Einspeisung und UB bzw GND als Masseleitung zu verwenden Werden mehrere Ger te von...

Страница 6: ...Folgesch den welche durch Fehler an diesem Ger t entstehen sind von der Gew hrleistung und Haftung ausgeschlossen Montage und Inbetriebnahme der Ger te darf nur durch Fachpersonal erfolgen Es gelten a...

Страница 7: ...mA Sensor Optical NDIR sensor non dispersive infra red technology with manual calibration via zero button with automatic calibration fixed Measuring range 0 2000 ppm Output 0 10 V Relay output withou...

Страница 8: ...500 ppm The device detects this condition and performs the calibration automatically It is sufficient to open the windows or set the air conditioning system to use outdoor air at regular intervals an...

Страница 9: ...voltage supply it is to be ensured that all positive operating voltage input terminals of the field devices are connected with each other and all negative operating voltage input terminals reference...

Страница 10: ...vice are excluded from warranty or liability These devices must be installed and commissioned by authorised specialists The technical data and connecting conditions of the mounting and operating instr...

Страница 11: ...ypique 2 9 VA 24 V ca typique Pointe de courant 200 mA Capteur capteur optique NDIR technologie infrarouge non dispersive avec talonnage manuel via la touche z ro avec talonnage automatique r gl par d...

Страница 12: ...na t cet tat de mani re autonome et r alise l talonnage automatiquement Il est suffisant d ouvrir les fen tres intervalles r guliers ou de r gler le syst me de ventilation sur air ext rieur tout en vi...

Страница 13: ...appareils sont aliment s en 24V ca il faut veiller ce que toutes les entr es de tension positives des appareils de terrain soient reli es entre elles de m me que toutes les entr es de tension n gative...

Страница 14: ...il Nous d clinons toute responsabilit ou garantie au titre de tout dommage cons cutif provoqu par des erreurs commises sur cet appareil L installation et la mise en service des appareils doit tre effe...

Страница 15: ...e di picco 200 mA Sensore sensore ottico NDIR tecnologia a infrarossi non dispersiva con calibrazione manuale tramite tasto zero con calibrazione automatica impostazione fissa Range di misura 0 2000 p...

Страница 16: ...CO2 Per la tecnica di calibrazione automatica del sensore necessario semplicemente cambiare l aria regolarmente concentrazioni di CO2 350 500 ppm L apparecchio riconosce questo stato autonomamente ed...

Страница 17: ...r l alimentazione 15 36 V DC e l ingresso UB o GND per la terra Quando pi dispositivi sono alimentati da un unica alimentazione con ten sione 24 V AC necessario assicurarsi che tutti i terminali di in...

Страница 18: ...apparecchi dovuti ad es all induzione elettrica utilizzare cavi schermati evitare la posa in parallelo delle linee conduttrici di corrente e rispettare le norme di compatibilit elettromagnetica Utili...

Отзывы: