INSTALLATION
The transformer is intended for use in dry premises only. Sufficient space (50mm) for air
circulation should be left around the transformer to ensure cooling of the device. Do not cover
completely or embed the transformer.
Prior to connection make sure that the data indicated on the information table of the transformer
match the supply power parameters. For good results, plan thoroughly all installation activities.
Make sure that the cable length is sufficient for connection.
Follow safety instructions, in insecure cases contact professional electricians:
o
Turn off the main fuses and check with a voltage tester that all wires are definitely tension
free. If in doubt, a electrician must do the installation work.
o
First connect the secondary circuit (SEC / 12 V DC), by removing the safety cover of the
transformers secondary circuit.
o
Ensure the polarity of the led cables (red + , black -)
o
When you have connected the secondary side of the led devices you can do the primary
circuit connections (PRI/200-400 V AC) Attention! Make sure that the power of all circuits
are turned off before doing the connections.
o
After connecting the two primary wires, reattach the cover caps and when needed attach
the transformer in a safe place with two screws.
o
Turn the mains fuse on.
INSTALLATION
For good results, plan thoroughly all installation activities. Make sure that the cable length is
sufficient for connection. Attention! The LED lamp is equipped with heat resistant silicone cables.
Pay special care to their installation.
Содержание LATERNE 46324
Страница 23: ...o o SEC 12 o o PRI 200 400 o o o 170 C o 125 C o o 20...
Страница 24: ...20 12 Nikkarien Oy www nikkarien fi...