ELECTRICAL CONNECTIONS
The steam generator will be semi-permanently connected to the electricity mains. Local regulations
must be observed.
Steam
Power 400V-415V 3N~ 230V-240V 1N~ 230V3~
Room size
generator
KW
Amp Amp
Amp
m³ *)
HSS 34
3.4
5
15 / 14
8
1.5-2.5
HSS 47
4.7
7 / 6,5
20 / 19
12
2.5-5
HSS 60
6.0
9 / 8
26 / 25
15
5-7
HSS 77
7.7
12 / 11
33 / 32
19
7-10
HST 90
9.5
15 / 13
24
10-12
HST 120 12.0
19 / 17
30
12-15
HST 140 14.0
23 / 21
35
15-18
All electrical connections should be completed by a qualified electrician.
*) Walls of concrete, brick or stone and cold wall lining materials will require a higher power
output to heat the room. Air conditioning and good ventilation may also need more power.
The required power can be estimated using the following formula.
Capacity (m3) x K1 x K2 = Required power (kW)
Ventilation
K1 = 0.75
No ventilation
K1 = 0.52
Acrylic walls
K2 = 1.00
Light wall: board + tiles
K2 = 1.25
Heavy wall: stone, co tiles
K2 = 1.50
Two-stage control of the steam generator:
The heat elements have a two-stage control.
Not 230 V 3~p.
Example:
Set temperature is 43 °C. When this temperature is reached the contactor turns off two elements,
leaving one element connected via relay-switch on the circuit board, ensuring steady temperature
and continuous steam production for the duration of the steam bath. Once the temperature has
dropped by one degree (1 °C), all the elements are switched back on. If the temperature rises by one
degree (1 °C), all the elements will be switched off. .