Saunatec HELO HSS M 34 Скачать руководство пользователя страница 4

 

4

 
 
STEAM GENERATOR CONNECTORS 

 

 

Water and Steam connection 
 

Connect the ¾" flexible water pipe (included in the package) from the water connection in the 
equipment (see picture) to the cold water supply in the building. Water pressure must fall between 
0.2 and 10 bar. The water supply must have a stop valve, which can be used to isolate water supply 
for maintenance or when steam room is not used for extended periods. 

 
Installation must comply with local requirements 

 
In the steam pipe connection it is recommended to use at least 18x16mm (steam generator power 
3.4 kW - 9.5 kW) and 22x20 mm (steam generator power 12.0 kW - 14.0 kW) copper pipe or 
similar size silicone pipe suited for high temperatures. The steam pipe diameter must be constant 
throughout. Subject to the location of the generator the steam pipe should rise or fall on a steady 
gradient from generator to steam room. It is essential that the pipe 

MUST NOT

 include traps as the 

water which collects will cause restricted steam flow and spitting at the steam head. Any water from 
condensation in the pipe must be allowed to flow freely back into the steamer or into the steam 
room. If an essence pump has been fitted to the steam generator, the pipes must 

always

 be on a 

downward gradient from the generator to avoid any chemicals reaching the tank. The steam pipe 
should be maximum length 5 meters and fully insulated both for safety reasons and to minimise 
condensation. 
 

WARNING: Hot steam can cause burn injuries. 
 

The electric magnetic vent used for emptying the generator’s tank is fitted to the flushing pipe. A 
manual flushing stop valve can also be used with the generator. (Optional extra) 

It is good practise to empty the tank after each use. This will maximise the life of this 
equipment and reduces chalk/scale build-up. 

 
 
 
 
 
 
 
 
 
 

Main switch

Water connection

Excess pressure 
vent and descaling 
(optional)

Electricity connection

Steam exit

W

D

H

  

 Measurem ents

   

HSS           HST

H  = 325      H  = 410
W = 185      W = 200
D  = 315      D  = 400

Control module
cable

Cable for
the flush vent

Содержание HELO HSS M 34

Страница 1: ...1 SAUNATEC GROUP Ltd HELO HSS M and HST M STEAM GENERATOR User and Installation Guide for models HELO HSS M 34 47 60 77 HELO HST M 90 120 140 314 SHS 64 C...

Страница 2: ...gramme Automatic fill and water level setting Floor or wall mounting Digital control module Temperature control Time control Light control Control module may be fitted on inside or outside of steam ro...

Страница 3: ...ures above and to the sides is no less than 30 cm Consider the space needed around the generator for routine maintenance For the emptying of the tank there should be drainage available in the vicinity...

Страница 4: ...pe MUST NOT include traps as the water which collects will cause restricted steam flow and spitting at the steam head Any water from condensation in the pipe must be allowed to flow freely back into t...

Страница 5: ...oning and good ventilation may also need more power The required power can be estimated using the following formula Capacity m3 x K1 x K2 Required power kW Ventilation K1 0 75 No ventilation K1 0 52 A...

Страница 6: ...1 N 3 N N N N N V2 V1 H1 H2 N L PE OLEA 72 S1 S2 High level Water valve drain 230 V AC Water valve filling 230 V AC Heater fuse Elements Contactor LC1 LC2 B1 B2 T1 T2 A K S1 S2 TX RX 5 0 Serial traffi...

Страница 7: ...5 0 354 SHS 33 A 1 5 2 6 Level probe Earthing for cover High level Water valve drain 230 V AC Water valve filling 230 V AC Heater fuse Elements Contactor Serial traffic to MIDI control On Off Push but...

Страница 8: ...230 V AC Water valve filling 230 V AC Thermofuse Contactor LC1 LC2 B1 B2 T1 T2 A K S1 S2 TX RX 5 0 Control keyboard On Off pushbutton Thermostat Alarm 12 V DC Light control opto max 24 V DC 50 mA 1 6...

Страница 9: ...the separate installation and connection diagrams Steam nozzle s must be fitted approx 20 40 cm from the floor either under the seat or on the wall in a position such that hot steam cannot burn the fe...

Страница 10: ...ashing Bathing time selection button time display flashing plus button for increasing the setting of time and temperature minus button for decreasing the setting of time and temperature Light control...

Страница 11: ...ed to LC1 When the lights button is pressed a transistor on the circuit board transfers the voltage into LC2 which carries out the actual light unit control PUSH BUTTON Functions of the button When st...

Страница 12: ...ite is designed to clip fit onto the control housing This bezel is removed with the supplied tool Using this tool lightly press the locking pin in each of the 4 holes around the perimeter whilst pulli...

Страница 13: ...he flush and rinse After the cycle has run the generator will await a new start up command ELECTRIC FLUSHING VENT Drain Kit M Optional extra HSS M and HST M generators flushing vent installation Use P...

Страница 14: ...removal of lime from the tank Testing water quality and de scaling for HSS M and HST M generators Test strips included in the test pack supplied with the generator are used as follows Submerge the tes...

Страница 15: ...n fitted with an automatic or a manual flushing valve Automatic flushing valve The generator will empty and rinse itself after 15 minutes of idle time After the first flush generator is started again...

Отзывы: