background image

12

13

SI-200

SI-200

Open the shutter 
and gently push 
the powered hose 
in the opening.

Connect the  
electronic control 
handle to the 
telescopic tube.

Connect the 
telescopic tube  
to the Powerclean 
head (PB1).

To extend the length 
of the telescopic tube 
slide the lock down. 
To reduce the 
extension, slide  
the lock up.

Gently pull out the 
power cable and 
connect it to the 
power socket.

1

2

3

4

5

PB1 Powerclean Head

Switch on 
the vacuum 
cleaner, from the 
electronic control 
handle or from the 
vacuum cleaner.

6

Switch on/off the 
Powerclean head  
by pressing on  
the brush button  
on the electronic 
control handle. 

7

When the Powerclean head (PB1) is placed in the park position on the unit; the vacuum 
cleaner enters stand-by mode and the Powerclean head (PB1) switches off for safety 
reasons. When restarting the Sauber Intelligence, the Powerclean head (PB1) must be 
switched on again.

Green Light:

 The electric powerclean head is in operation.

Red Light:

 Automatic switch off function – the powerclean head is blocked and the motor 

is switched off automatically. When the motor of the brush has switched off, turn the 
cleaner off, remove the item that is blocking the brush and turn the cleaner on again.

Connect the 
Powerclean  
brush (PL1) to  
the powered hose.

Open the shutter 
and gently push  
the powered hose 
in the opening.

Gently pull out the 
power cable and 
connect it to the 
power socket.

Switch on the 
vacuum cleaner from 
the electronic control 
handle or from the 
vacuum cleaner.

Switch on/off  
the Powerclean 
brush by pressing 
on the brush button 
on the electronic 
control handle.

1

2

3

4

5

The green light turns on to 
indicate that the Powerclean 
brush is operating. Keep 
moving the nozzle to 
avoid wearing of the fabric 
and overheating of the 
Powerclean brush.

6

PL1 Powerclean Brush

VACUFLEX

 TM

 is a patented flexible bottom plate for deep cleaning.

IMPORTANT! Always turn off the vacuum before making any 
adjustment to the Powerclean brush.

To remove VACUFLEX

 TM

, hold the plate at one side edge.  

With little force, turn it down over the small side ramp.  
The locking of the plate will lift and automatically release itself.

1

VACUFLEX

Removal of VACUFLEX

TM

Содержание Intelligence SI-200

Страница 1: ...User Manual SI 200...

Страница 2: ...2 3 SI 200 SI 200 We congratulate you for choosing Sauber Intelligence the first class cleaning system Before operating the Sauber Intelligence please read this instruction manual carefully and keep i...

Страница 3: ...ng surface in order to prevent damage to the filter If the air inlet floor head or the telescopic tube is blocked switch off the cleaner straight away and remove from the mains power First clear the b...

Страница 4: ...winder foot pedal J ON OFF foot pedal K Aroma compartment not shown L Powered hose M Electronic control handle N Telescopic tube O Automatic floor head P Small combination tool Q Radiator brush R Cre...

Страница 5: ...clear the blocked substance before attempting to start the vacuum cleaner again Please do not expose the electrical hose to water or clean it with water Damaged cables should be inspected by an autho...

Страница 6: ...um cleaner will start in Intelligent Power Control IPC mode To switch off the vacuum cleaner press the ON OFF foot pedal For short breaks insert the nozzle in the side parking position the motor will...

Страница 7: ...the powerclean head is blocked and the motor is switched off automatically When the motor of the brush has switched off turn the cleaner off remove the item that is blocking the brush and turn the cle...

Страница 8: ...brush PL1 on curtains and other hanging canvas 2 Assembly of VACUFLEXTM Cleaning with VACUFLEXTM Cleaning without VACUFLEXTM Application Danger and Live Parts Within Always unplug the vacuum from main...

Страница 9: ...e crevice nozzle when vacuuming narrow spaces such as corners and grooves 2 1 6 3 4 5 Accessories Open the lid and push the powered hose into the blow port connection Use the buttons on the vacuum cle...

Страница 10: ...cation Motor overheating cool down for 30 45 mins If the symbol appears again contact the closest Sauber service centre Powerclean brush or Powerclean head ON AUTO function ON Intelligent Power Contro...

Страница 11: ...ntelligence is recommended by the German Allergy and Asthma Federation DAAB as a result of scientific tests run by the independent institutes T V NORD and GUI Nominal power consumption 80 W Voltage 24...

Страница 12: ...being needed please contact International Cleaning Solutions Pty Ltd Level 1 Building 2 Brandon Business Park 530 Springvale Road Glen Waverley Vic 3150 or on 1800 728 237 Monday Friday 9am 5pm EST T...

Страница 13: ...3 YEAR P REMIU M W A R R A N T Y 3 YEAR P REMIU M W A R R A N T Y V4 01 04...