KDB-GOM
Series
- 85 -
No
7
Part name
Air pressure switch
Replacement steps
Disassemb
ly
①
Unplug the boiler from the electric outlet.
②
Open the front cover.
③
Separate the two wires (yellow) connected to the air pressure switch.
④
Separate the air pressure switch by removing one screw from the board holding it.
⑤
Separate the air pressure switch connecting hose.
A
sse
m
b
ly
①
Fix the air pressure switch to the board by screwing one screw.
②
Connect the two wires to the air pressure switch.
③
Assemble the hose connecting the air pressure switch.
④
Close the front cover.
⑤
Plug the boiler into the electric outlet.
Caution
1. Make sure there is no shaking after assembly.
2. Make sure the connecting jack is correctly assembled.
④