background image

 
 

8

 

 

LED 

Behavior 

Status 

Note 

by 

hardware. 

Off 

Your terminal is not 

connected to any 

power source. 

Controlled 

by 

hardware. 

1.3.2

 

Buzzer 

You can define the status the vibration indicates using 

the SDK. 

Sound 

Status 

1 Short Beep 

A key is pressed. 

A good scan. 

An error occurred. 

2 Short Beep 

The battery is low. 

4 Short Beep 

Battery is too low to turn off 

terminal. 

1.3.3

 

Vibration 

You can define the status the vibration indicates using 

the SDK. 

Vibration 

Status 

Vibrate 

A good scan. 

Содержание Argox AP Series

Страница 1: ...User s Manua Data Collector PI XXXX AP XXXX SP XXXX PE XX X 0 9 A Z a z dash or blank...

Страница 2: ...ns may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference...

Страница 3: ...mits set forth for an uncontrolled environment The equipment must not be co located or operating in conjunction with any other antenna or transmitter This device complies with Part 15 of the FCC Rules...

Страница 4: ...under the Display Grant section of www fcc gov eot ea fccid after searching on FCCID NBF PI 1X30 RF Exposure Information SAR This device meets the government s requirements for exposure to radio wave...

Страница 5: ...t circuit heat the battery or dispose of in fire Store battery pack in a proper place Do not expose to temperature above 60 140 Use specified charger only Please dispose of the used batteries followin...

Страница 6: ...i Release Note Version Date Note V1 0 02 22 2017 Initial release...

Страница 7: ...Vibration 8 1 4 Keypad 9 1 5 Power source 14 1 5 1 Inserting or replacing battery 15 1 5 2 Charge the battery 18 2 Get started 20 2 1 Set up your terminal 20 2 2 User interface 21 2 3 Connection 23 2...

Страница 8: ...4 Environment 35 3 2 5 Test 36 3 2 6 System info 38 3 3 Supervisor Menu 39 3 3 1 Remote Link 40 3 3 2 Format disk 43 3 3 3 Setting 44 3 3 4 Information 49 4 Applications 50 5 Troubleshooting 51 5 1 H...

Страница 9: ...t wear off between uses Battery cover open detection When the switch of the battery cover is up the system automatically saves your files and shut down Large flash memory PI series offers more flash m...

Страница 10: ...2 1 1 Unpacking Make sure all of the following items are included in your package PI series Quick Start Guide USB Cable or RS 232 Cable with USB power cord Holder Option Hand Strap...

Страница 11: ...nd inspect for shipping damage If you discover any damage contact the shipping company and file a claim Argox is not responsible for any damage incurred during shipping Save all package materials for...

Страница 12: ...ttom 1 LED Three LEDs 2 LCD Display A mono LCD 3 Keypad A 25 key keypad 4 Battery Cover The battery cover 5 Battery Cover Switch Open and close the battery cover 6 Reading Window The bar code reading...

Страница 13: ...5 8 Connector A port to connect computer 1 2 2 Holder Option The holder is used to hold your terminal in its standing position In the bottom of holder make sure cable wire is installed as below...

Страница 14: ...current status 1 3 1 LED Your terminal has three LEDs on the upper left corner They have different behavior The table below gives information about the status they indicate LED Color Scan LED Green Re...

Страница 15: ...e SDK Flashing orange User defined Use SDK Off No data transmission or user defined Use SDK BT Wi Fi LED Solid blue Your terminal is connected through Bluetooth or Wi Fi Flashing blue Your terminal is...

Страница 16: ...can define the status the vibration indicates using the SDK Sound Status 1 Short Beep A key is pressed A good scan An error occurred 2 Short Beep The battery is low 4 Short Beep Battery is too low to...

Страница 17: ...a bar code Cursor keys Up Move the highlight bar up Fn Up Open Message Menu Down Move the highlight bar down Fn Down Adjust the backlight brightness The brightness repeats the sequence 0 1 2 3 Left M...

Страница 18: ...klight brightness The function of F0 F9 Fn 0 9 can be defined using an SDK ENT The Enter key 1 Enter a menu 2 Select an option BS The Backspace key 1 Delete a character to the left of the cursor Numer...

Страница 19: ...M N O 7 1 Enter the number seven 2 Enter the letters P Q R S 8 1 Enter the number eight 2 Enter the letters T U V 9 1 Enter the number nine 2 Enter the letters W X Y Z 0 1 Enter the number zero 2 Ente...

Страница 20: ...ination key You can use the key combinations to enter different menus or modes Press and hold the combination of keys until your terminal responds 3 9 Power System Menu 1 3 0 Power Supervisor Menu 1 3...

Страница 21: ...n t be resolved in any other way BIOS reset it is the same as BIOS default see Supervisor Menu It resets all your terminal settings including the password of Supervisor Menu Warm reset It restarts you...

Страница 22: ...pply with the USB or RS 232 cable Cable Type Charge your batteries Supply power without batteries Need to use with a power supply USB Yes Yes No RS 232 No No Yes Warn Do not collect data while plug th...

Страница 23: ...a after work or keep two AA batteries in case Caution Do not mix old batteries and new batteries or standard carbon zinc with alkaline batteries Remove batteries if product is not to be used with for...

Страница 24: ...16 2 Inserting two batteries as indicated inside battery compartment 3 Close the battery cover as follow...

Страница 25: ...17 4 Make sure cover is closed and slide two latch back...

Страница 26: ...nnecting the USB cable to your terminal and use a power supply When your batteries are fully charged the Charger LED turns to solid red Important To protect power source PI series can not be powered o...

Страница 27: ...19 Note The triangle mark should be face up when you want to plug connecter in to PI series...

Страница 28: ...al and make connection to computer 2 1 Set up your terminal 1 Choose one to power on your terminal Open the battery cover and Install two AA batteries Connect your terminal to your computer using USB...

Страница 29: ...Options Items in the menu Status bar It displays the information about your terminal Input method The way you enter data You can enter numbers lowercase or uppercase characters Time The current time M...

Страница 30: ...or Wi Fi function it displays an icon without waves If connection is successful the icon will show waves Power source If your terminal is connected to a direct power supply USB or RS 232 it displays a...

Страница 31: ...t is a unique protocol from Argox development Visit Argox website below to download application http www argox com content2011 php sno 0000033 Linking port Transmit raw data 1 Byte a time Developer ca...

Страница 32: ...essage menu to send message when the connection successful Use Remote link to connect PC with USB Step 1 After link USB cable between PI series and PC press Power key to open PI series Step 2 Move cur...

Страница 33: ...25 Step 4 Choose Connect Step 5 In PhoenixVoler or Everlink Click Comm setup will show the model number Successfully connected to PC...

Страница 34: ...ou receive Read Msg It shows the message you sent Send Msg To Everlink Send to is 9000 To ControlCenter Send to is 9001 To otherPI series device Send to default depends on SN last four number To chang...

Страница 35: ...your terminal between uses Attach the hand strap is a useful way to resolve these issues You can wrap the strap around your hand to secure it to your hand or hang it on your hand to have both hands fr...

Страница 36: ...2 Thread the big loop into the small loop and pull the big loop to tie a knot Important Use hand strap when you collect barcode in case drop accident PI series might shut down to protect data after dr...

Страница 37: ...and Supervisor Menu is for system administrators or engineers Besides press Fn can enter Message Menu This chapter provides information about these menus 3 1 User Menu User Menu includes three frequen...

Страница 38: ...ram it will tell you No program file For more information about how to connect to a computer and download programs from it see PhoenixVoler or Everlink User guide 3 1 2 Remote Link It is for you to co...

Страница 39: ...e If you want to connect via Bluetooth or WI FI you need to enter Supervisor Menu and set up Bluetooth connection or WI FI connection first After completing the setting you can connect your terminal f...

Страница 40: ...function barcode default 3 1 4 Information It displays your terminal s information IPL The IPL version BOOT The boot version Kernal The kernel version Scanner The scanner s firmware version SN The se...

Страница 41: ...you can change system settings to meet your need and run some tests to see if your terminal is working properly Press key 3 9 Power to enter system menu 3 2 1 Remote Link See the description in Remot...

Страница 42: ...lt your terminal has two disks C and D 3 2 3 Timer setting Set date time You can set date and time here Set time format You can set the time format here It provides the 12 hour or 24 hour clock and on...

Страница 43: ...st the darker the screen 1 10 Backlight timer It determines how long the backlight stays on after you press a key 1 65535 Set 0 will always on Auto off timer It turns off your terminal after a certain...

Страница 44: ...ll turn it off 3 2 5 Test It provides various tests for you to check your terminal system Memory test It checks if the memory can be written and read properly Note that this test removes all data stor...

Страница 45: ...run this test For more information about the port setting see the description in Setting in Supervisor Menu After you set a port do this 1 Select the port you want to test and press ENT 2 Your termin...

Страница 46: ...38 3 2 6 System info See the description in Information in User Menu...

Страница 47: ...enu 1 3 0 PWR Supervisor Menu provides advanced settings for you to configure To protect the settings from being changed easily you need to enter a password to access the menu By default the password...

Страница 48: ...Everlink or PhoenixVoler to computer Connect It connects your terminal to computer after you select an interface Remote I F Select It provides interfaces including COM port Bluetooth and WI FI Remote...

Страница 49: ...other devices to enter a PIN code when they try to connect to your terminal b Encryption It encrypts the connection to prevent data theft 4 Inquiry timeout It determines how long your terminal stops...

Страница 50: ...s WI FI It has three options 1 Setting 1 WI FI SSID a Set by search Search WI FI signal in the neighborhood b Set by keyin Type New SSID to connect the WI FI you prefer 2 Network It is the same as com...

Страница 51: ...he process need to wait about 3 15 seconds PI series will show the connect success of fail on the screen 3 Information It displays WI FI information 1 Remote port show the page is under remote port 2...

Страница 52: ...3 3 Setting It offers a variety of settings that you can change to meet your need Equipment ID Your terminal s ID The default ID is four zeros 0000 You can replace it with a new ID The ID needs to be...

Страница 53: ...u visited in User Menu every time you turn on your terminal 2 Reset The system displays the default screen in User Menu every time you turn on your terminal Status bar You can choose if you want to di...

Страница 54: ...Image When you turn on this feature you can scan both regular and inverted bar codes Preamble Add a character or characters before a bar code Postamble Add a character or characters after a bar code B...

Страница 55: ...u can change the language for the system to display items in the user interface It has two options English TC Traditional Chinese and SC Simple Chinese Linking port You can decide which port you want...

Страница 56: ...rface choose None Port IF setup It provides the settings of COM Bluetooth and WI FI For more information about the settings see Remote Link in Supervisor Menu Port info It displays the port informatio...

Страница 57: ...nformation IPL The IPL version BOOT The boot version Kernal The kernel version Scanner The scanner s firmware version SN The serial number HW Ver The PCBA Printed Circuit Board Assembly version HW Int...

Страница 58: ...PI series with files transmission message sending and history data function Control center Remote end of manage program can link multiple Everlink and provide Cloud operation Development application...

Страница 59: ...e Test to check keypad The system might be crush Use Scan Power key to warm reset or cold reset hold 5 seconds My terminal keeps turning itself off or can not open If you re using batteries check them...

Страница 60: ...and unplug the USB and try again Receive or transmit problem on RS 232 Check RS 232 connector is plugged correctly Check Remote Link set is COM port and select the same port on computer Restart PI se...

Страница 61: ...angle between the bar code and the terminal Change the distance between the bar code and the terminal Clean the scanning window slightly of the terminal make sure without scratch Enabled the bar code...

Страница 62: ...M 20 60 MB Flash Display White gray mono STN LCD 160 160 Indicator LED Blue Green and Red Beeper Vibration Motor Keypad 25 Alpha Numeric keys Including 10 function keys 3 programmable hot keys Accesso...

Страница 63: ...13 mil PCS 90 254 mm 13 mil 390 mm 13 mil Scanning rate 200 scan sec 100 scan sec Decode capability 1D barcode Code 11 Code 39 Code 93 Code 128 EAN 8 EAN 13 UPC A UPC E Industrial 25 Interleaved 25 S...

Страница 64: ...USB 2 0 RS 232 USB 2 0 RS 232 USB 2 0 RS 232 Expansion Storage Micro SD up to 16 GB Developing Tools Software Software Development Kit SDK Skywalker Proprietary application software generator Programm...

Страница 65: ...age Temperature 20 70 4F 158F Humidity 1 Operating Non condensed 10 90 2 Storage Non condensed 5 95 Impact Resistance 1 Terminal 1 5M 5ft Holder 0 9M 4 drops per 6 sides 2 IP54 Electrostatic Discharge...

Страница 66: ...on Disable Enable Transmission Preamble transmission Disable Enable Postamble transmission Disable Enable Code ID position Before code data After code data Code ID transmission Disable Proprietary ID...

Страница 67: ...image scan Disable Enable String setting Prefix characters setting 0 0x00 0xff ASCII code 12 characters Suffix characters setting 0 0x00 0xff ASCII code 12 characters Preamble characters settings 0 0x...

Страница 68: ...gits Enable One digit Enable Two digits Max code length 0 64 0 Min code length 0 64 0 Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting O 0x00 0xff ASCII code 1 or 2 bytes Code 39 Read Di...

Страница 69: ...15 0 Code ID setting 0x00 0xff ASCII code 1 or 2 bytes Format Standard Full ASCII Start stop transmission Disable Enable Code 93 Read Disable Enable Check sum transmit verify Disable Disable Disable E...

Страница 70: ...or 2 bytes Code 128 Read Disable Enable Check sum transmit verify Disable Disable Disable Enable Enable Enable Max code length 0 64 0 Min code length 0 64 1 Truncate leading 0 15 0 Truncate ending 0...

Страница 71: ...ytes Codabar Read Disable Enable Check sum transmit verify Disable Disable Disable Enable Enable Enable Max code length 0 64 0 Min code length 0 64 0 Truncate leading 0 15 0 Truncate ending 0 15 0 Cod...

Страница 72: ...um transmission Disable Enable Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting FF 0x00 0xff ASCII code 1 or 2 bytes Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC...

Страница 73: ...e Check sum transmission Disable Enable Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting F 0x00 0xff ASCII code 1 or 2 bytes Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 1...

Страница 74: ...0 Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting i 0x00 0xff ASCII code 1 or 2 bytes Interleaved 2 of 5 Read Disable Enable Check sum transmit verify Disable Disable Disable Enable Ena...

Страница 75: ...Enable Check sum transmit verify Disable Disable Disable Enable Enable Enable Max code length 0 64 0 Min code length 0 64 0 Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting i 0x00 0xff...

Страница 76: ...e length 0 64 0 Min code length 0 64 0 Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting 0x00 0xff ASCII code 1 or 2 bytes UK Plessey Read Disable Enable Check sum transmit verify Disable...

Страница 77: ...x00 0xff ASCII code 1 or 2 bytes Telepen Read Disable Enable Check sum transmit verify Disable Disable Disable Enable Enable Enable Max code length 0 64 0 Min code length 0 64 0 Truncate leading 0 15...

Страница 78: ...e Enable Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting A 0x00 0xff ASCII code 1 or 2 bytes Supplement digits None 2 digits 5 digtis 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128...

Страница 79: ...5 0 Code ID setting E 0x00 0xff ASCII code 1 or 2 bytes Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All Truncate expansion None Truncate leading zero Ex...

Страница 80: ...able Enable Enable Enable Max code length 0 64 0 Min code length 0 64 0 Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting B 0x00 0xff ASCII code 1 or 2 bytes China post Read Disable Enabl...

Страница 81: ...able Enable Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting R4 0x00 0xff ASCII code 1 or 2 bytes UCC EAN 128 emulation Disable Enable RSS Limited Read Disable Enable Truncate leading 0...

Страница 82: ...0 99 99 Min code length 0 99 1 Truncate leading 0 15 0 Truncate ending 0 15 0 Code ID setting RX 0x00 0xff ASCII code 1 or 2 bytes UCC EAN 128 emulation Disable Enable Italian Pharmacode 39 Read Disab...

Страница 83: ...75 Truncate ending 0 15 0 Code ID setting p 0x00 0xff ASCII code 1 or 2 bytes Leading A Disable Enable...

Отзывы: