EPC CODE WRITE DESIGNATION COMMAND

FUNCTION

Writes EPC code in RFID supply that supports EPC code.

FORMAT

<ESC>IP0n.nnn

PARAMETER

n = Data to be written (16 bytes fixed for 64 bit inlays) or (24 bytes

fixed for 96 bit inlays).

EXAMPLE

To write 64-bit EPC code “8000 0000 4000 0001” for label issuance in
RFID supply that supports EPC code:

<ESC>A
<ESC>V50<ESC>H50<ESC>BD3020654912345678904
<ESC>IP08000000040000001
<ESC>Q1
<ESC>Z

NOTES

Printing of multiple tags (QTY > 1) is available with this command. If
data is written to an RFID tag, labels are printed after sent EPC data
and encoded EPC data are automatically checked.

If EPC code writing could not be carried out (i.e. bad tag), a tag error
label is printed and an output is sent via EXT Port, PIN 3.

Data other than 0 to 9 and A to F will be considered a command error.
If used without print data, this command will not cause a label to feed
in the case of a successful tag encode.

EPC CODE READ DESIGNATION COMMAND

FUNCTION

Reads information of RFID supply supporting EPC code.

FORMAT

<ESC>IP1

RETURN STATUS 
FORMAT

STX (02H) . EPC code . ETX (03H)

RETURN STATUS LIST

STX (02H) = Starting code: 1 byte.
EPC Code = EPC Code; 16 bytes fixed.
ETX (03H) = Ending code: 1 byte fixed.

EXAMPLE

<ESC>A<ESC>IP1<ESC>Z

If  “8000 0000 4000 0001” is recorded in RFID supply that supply that
supports EPC code:

     02 = Starting code
     38 30 30 30 30 30 30 30 34 30 30 30 30 30 30 31 EPC
     03 = Ending code.

NOTE: In actuality, all data is continuous without spaces.

NOTES

This command cannot be combined with another command to
designate.

This command cannot be received during printing.

If the connection is closed before all status’ are returned to the host, the
tag data will not be correctly returned.

Содержание 9001147B

Страница 1: ...PN 9001147B RFID USER GUIDE Alien C1 UHF...

Страница 2: ...50A Nations Ford Road Charlotte NC 28273 Main Phone 704 644 1650 Technical Support Hotline 704 644 1660 Technical Support Fax 704 644 1661 E Mail satosales satoamerica com techsupport satoamerica com...

Страница 3: ...able connects the main circuit board to the RFID Reader The Reader is in turn connected to the antenna by its own antenna cable Through software configuration and hardware installation the printer is...

Страница 4: ...62 mm sealed in a shield case Antenna 16 x 118 x 1 6 mm RFID READER SPECIFICATIONS Name ALR 9930 module by Alien Technology Frequency 902 928 MHz Communication System Frequency hopping spectrum disper...

Страница 5: ...the printer detects an error condition such as head open receiving buffer full or when the user specified number of RFID errors has been reached Output 5 Print Start The printer will print one label...

Страница 6: ...default is 00 The range is 00 to 99 Sets the printer response after the REPRINT CONT has been reached When STOP is selected the printer will enter an error state that can be cleared by pressing the LI...

Страница 7: ...NEW from the menu options The Label Setup Wizard screen for Select Printer will display as shown below Click on the menu scroll down arrow and select the RFID printer driver relative to the printer o...

Страница 8: ...r the required dimensions to properly format for the print job at hand Click on the FINISH button when complete and the following Label Gallery screen will appear with a blank label present Click on D...

Страница 9: ...for a 96 bit selection twleve 12 digits must be used HEX Allows the data to entered using 0 through 9 and A through F The exact data is sent to the printer s chip For a 64 bit tag selection sixteen 1...

Страница 10: ...SATO RFID User Guide PN 9001147B Page 8 Click on the OK button when complete and the label will show up on the next screen with the RFID inlay outlined around the label Refer to the screen below...

Страница 11: ...e label with label fields Refer to the Label Galley Manual s Help Files for assistance as required Once complete click on FILE on the upper task bar select the Print option and then enter the desired...

Страница 12: ...EXT Port PIN 3 Data other than 0 to 9 and A to F will be considered a command error If used without print data this command will not cause a label to feed in the case of a successful tag encode EPC C...

Отзывы: