background image

Introduction 

 
Thank you for purchasing the Mini Infrared Thermometer Model SK-8700II.   
The  SK-8700II  is  conforming  to  the  Assessment  for  the  Japanese  Consumer  Law  on  laser 
equipment 

and carries “PSC” mark. 

 
This product is designed to measure temperature using a non-contact method. Do not use it for 
other purposes. Read this manual thoroughly before using the SK-8700II. Keep the manual in a 
safe place for future references whenever necessary. 
 
 

WARNING 

 

                  Beware of explosion! 

 
The SK-8700II is not explosion-proof. Never use it in an atmosphere containing flammable gases. 

 
Beware of laser marker! 

 

Do not look into the laser marker or point it at anybody's eyes. Doing so may damage your eyes. 
Keep the unit out of reach of children. 
 

  If you have any questions, contact the dealer from which the unit was purchased, or our service 

network. 

 
 
 

      Notes on Use 

 

Be sure to observe the following precautions in order to use this unit correctly. 
 

  Be careful of the following when the laser marker is active. 

. Do not stare into the laser marker. 
. Do not point the laser marker at anybody. 
. Keep the unit out of reach of children. 

  Do not use this unit as a clinical thermometer. 

  This is a non-contact thermometer. Do not let the unit touch the object to be measured. If the 

unit touches a hot object, it may result in measurement errors or failure. 

  Never disassemble or modify this unit. Doing so may result in failure. 

  Do not drop this unit or apply vibration/impact to it. This unit is a precision instrument. 

  Do not use this unit in a place exposed to direct sunlight or near heating equipment.   

  Doing so may result in measurement errors or deformation/discoloring of the casing. 

  This thermometer is designed for use in the ambient temperature range of 0 to 50°C at 80% RH 

or less. Using the unit outside the specified range will result in failure. 

  Do not use this unit in a dusty environment. The accuracy of measurement is affected by dust or 

dirt on the lens. Always wipe off dust and dirt after each use. For details, refer to "Maintenance". 

  Do not touch the measurement window with a sharp or hard object. Doing so may damage the 

lens, causing loss of measurement accuracy.   

  Do not use this unit in an environment where electrical noise is generated. Doing so may result 

in unstable display or larger errors. Also, do not bring the unit close to a charged object. 

Содержание SK-87002

Страница 1: ...Instruction Manual No 8261 00 Infrared Thermometer Model SK 8700Ⅱ 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan https www sksato co jp en M 07 ...

Страница 2: ...Keep the unit out of reach of children Do not use this unit as a clinical thermometer This is a non contact thermometer Do not let the unit touch the object to be measured If the unit touches a hot object it may result in measurement errors or failure Never disassemble or modify this unit Doing so may result in failure Do not drop this unit or apply vibration impact to it This unit is a precision ...

Страница 3: ...ively the measurement accuracy may be affected Wait for a while for the unit to properly adapt to the ambient temperature For a change of temperature of 10ºC or more wait for at least 30 minutes before measurement Overview The SK 8700II is a non contact type infrared thermometer which detects the infrared energy emitted from an object and converts it into a temperature reading The product can meas...

Страница 4: ...e seconds Lens cap Prevents dust or foreign matter from entering the measurement window infrared radiation sensing section Also it protects users from viewing the laser in case the laser marker is activated accidentally Vinyl cover Protects the unit when dropped and keeps out dirt or dust during storage ...

Страница 5: ...n matter in the measurement window Also it protects users from viewing the laser in case the laser marker is activated accidentally LCD Displays the temperature reading and other related information Measurement key Activates temperature measurement Backlight ON OFF key Sets the backlight function on or off Laser marker ON OFF key Sets the laser marker function on or off 1 2 LCD 7 segment display D...

Страница 6: ...ry life may be shortened 3 Putting Vinyl cover onto the Thermometer It is recommended to use the thermometer with the vinyl cover attached The vinyl cover will help absorb shock in case the unit is dropped accidentally and protect the unit from becoming dirty during use The thermometer is shipped in a vinyl cover 1 Hold the opening of the vinyl cover wide when inserting the unit 2 Fix the snap fas...

Страница 7: ...le light of wavelengths in the visible region 400 nm through 700 nm with an output level approx 1mW or less that is normally regarded harmless with respect to humans physical defense capabilities 5 Setting the Backlight While the power is on press the backlight ON OFF key to set the backlight on or off While the backlight key is on the LCD is illuminated in green so that the value displayed on the...

Страница 8: ...urface temperature of the glass 4 Release the measurement key The displayed value can be held for approximately five seconds 5 After five seconds the power is automatically turned off auto power off function 6 When the measurement is finished put the lens cap on the measurement window 8 Notes on Measurement 8 1 Measurement Spot Size The measurement spot size of this thermometer changes in accordan...

Страница 9: ...Measuring an object of 316 C or more may damage the infrared lens and cause loss of measurement accuracy Never measure an object whose temperature is outside the allowable temperature range 8 3 Measurement of an object with an emissivity other than 0 95 Apply heat resistant paint or tape that has an emissivity close to 0 95 to the object to be measured Since the emissivity of metals is lower than ...

Страница 10: ...below when a problem occurs before consulting your dealer for repair Problem Possible Cause Remedy Power does not turn on Battery power is insufficient Replace the battery 6F22 006P See Replacing the Battery If the power does not turn on even after replacing the battery an element inside the thermometer may have been damaged If the element inside the unit has been damaged by impact or drop the uni...

Страница 11: ...K 8700II Measuring range 20 C to 315 C Accuracy 2 C at 20 C to 100 C at 23 C 5 C 2 Reading at 101 C to 315 C Calibrated by Black body emissivity at 0 95 Resolution 1 C Repeatability 1 C Emissivity Fixed at 0 95 Distance to Spot size D S 8 1 Detector Thermopile Spectral response 6 to14μm Response time 0 5 second Laser sighting 1 point Class II Laser use less than 1mW of power Operating ambient 0 to...

Страница 12: ......

Отзывы: