Features 

-  Pocket-size, easy to carry 

-  Measurement of wind velocity, temperature and humidity is possible. 

-  Display of various calculated values 

  The wind chill factor, Beaufort wind scale, dew point and wet bulb temperature can be calculated and 

displayed. 

-  Auto power-off function 

  This function is to conserve battery power for user from forgetting the turn-off the power of this unit. 

 
 

1. Names and Functions of Components 
 

1-1. Main unit 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  LCD display 

   

: Display the measured values and the operating status of the unit. 

               

*

For more detail, please refer to the section “1-2. LCD display panel”. 

  HOLD/

l

  key   

: Pressing this key turns the power on or off.   

  UNIT/MODE key 

: Use to switch the measured unit or measurement mode. 

  Wind velocity sensor 

: The wind velocity is measured. 

  Temperature/Humidity sensor 

: The part which the temperature and humidity are measured. 

  Outlet for external temperature sensor 

: The part which the external sensor is attached 

  Battery lid/battery compartment 

 

 

 

: This lid covers the coin cell battery (CR2032) compartment. 

 

 

 

 

 

 

 

Содержание PC-53D

Страница 1: ...Instruction Manual No 7650 20 Mini Anemometer Model PC 53D 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english O 02...

Страница 2: ...ically noisy environments results in unstable display increased error If the unit is left in a car during summer time heat from sunlight may results in failure Do not leave it such a place As measurin...

Страница 3: ...Components 1 1 Main unit LCD display Display the measured values and the operating status of the unit For more detail please refer to the section 1 2 LCD display panel HOLD l key Pressing this key tu...

Страница 4: ...battery is displayed 1 Remove the battery lid by turning it counter clockwise by using a coin or the like 2 In case of replacing a battery take out the used battery 3 Insert the coin cell battery CR2...

Страница 5: ...lay the dew point temperature by calculating from temperature and humidity g Wet bulb Temperature Measurement Mode Wet bulb Measurement Mode is to display the Wet bulb temperature by calculating from...

Страница 6: ...Auto power off function If the unit is not operated for approximately 5 minutes the power will be automatically turned off This Auto power off function conserves battery power even if you forget to tu...

Страница 7: ...n measuring range Wet bulb temp display range 5 0 to 49 0 C display value calculated from temperature and humidity within measuring range Measurement sampling time about 1 second As for the wind veloc...

Страница 8: ......

Отзывы: