 This instrument is not waterproof. Do not place it in water or use it where it may be splashed with water. 

-

 When used outdoors, keep the unit out of rain or water splashes. If it becomes wet, the unit may fail. 

-

 If the unit will not be used for a long period of time, always remove the battery. Otherwise, the battery power 

may be wasted and the battery fluid may leak, resulting in malfunctions. 

-

 Keep the battery out of reach of children. If a child swallows a battery accidentally, consult a doctor 

immediately. 

-

 Do not dispose of used battery in a fire. 

-

 For environmental protection, dispose of used battery in compliance with local rules and regulations. 

-

 Do not wash or wipe this unit with alcohol, thinner, or other solvents. If the unit becomes dirty, wipe it with a 

tightly-wrung towel or the like that has been dipped in warm water with a neutral detergent. 

-

 Do not alter, pull forcibly, bend or bind the sensor probe, as doing so may cause a break in the probe. Also, 

do not place heavy objects on the cord or heat it, as doing so damage the cord. 

-

 When measuring, do not let the sensor probe come in contact with the human body. 

-

 When the unit is used for the first time or after it has been stored for several days, the pH measurement 

response may be slower. In such cases, immerse the sensor probe electrode in either the pH standard 
solution or water and let it stand for one hour.    For more accurate measurement, immerse it 12 hours at 
least in the pH 4 standard solution before use. * (Do not turn on the unit during this immersion time.) 

-

 The sensor probe electrode of this unit may be damaged or its useful life may be shortened if it is used for 

liquids such as organic solvents, oils, adhesives, strong acids (pH 0 to pH 2), strong alkalis (pH 12 to pH 14) 
and surface-active agents. 

-

 The pH reading may become unstable when pure water is measured. 

-

 If the pH standard solution contacts the skin (hand), immediately wash the contaminated skin with running 

water. If the solution gets into the eyes, immediately rinse with water and consult a doctor. 

-

 Keep the pH standard solution out of reach of children. If accidentally ingested, consult a doctor immediately. 

-

 When using the AC adapter (optional), do not connect or disconnect the power cord with wet hands. 

Otherwise, electrical shock or short-circuit may occur. 

 
 
 
 

Installing and replacing battery 

 

(1) Install the battery before connecting the probe to the unit. 

Remove the probe from the unit before when replacing battery,   

(2) Remove the screw holding the battery cover by turning it counterclockwise with a Phillips screwdriver (be 

careful not to be missing the screw). 

(3) When replacing the battery, remove the old battery (6F22, 006P). 

(4) Install a new

 

9V battery (6F22, 006P) by referring to the polarity marks (+ and -) on the battery compartment. 

(5) Place the battery cover on the unit and secure it to the unit with the screw. 

Note: When "BAT" is lit on the LCD, immediately replace all the battery with new ones. 

 

Otherwise the measurement accuracy may be affected or malfunction may occur. 

 

9V battery (6F22, 006P) is available at convenience stores, home centers and electric appliance 
stores. 

 

 

Содержание 6400-00

Страница 1: ...Instruction manual for No 6400 00 Handy type pH meter Model SK 620PH No 3 Nishi Fukudacho Kanda Chiyodaku Tokyo 101 0037 Japan URL http www sksato co jp english M 09...

Страница 2: ...pH meters The solutions are not for drinking Never try to drink it If accidentally ingested consult a doctor immediately For any other inquiries contact the store where you purchased the instrument or...

Страница 3: ...functions Main unit 1 Display Displays measurement readings or status of the unit 2 PWR key Press this key to turn on the unit To turn off the unit press the key again 3 CAL key Enters the calibration...

Страница 4: ...plug LCD 12 Display of pH or mV Displays pH values or mV values in the measurement mode Display the calibration values in the calibration mode 13 Display of temperature Displays temperature values in...

Страница 5: ...he SK 620PH be sure to observe the followings This is a precision instrument Be careful not to drop or knock it The operating temperature range for this instrument is 0 to 50 C and a relative humidity...

Страница 6: ...ndard solution before use Do not turn on the unit during this immersion time The sensor probe electrode of this unit may be damaged or its useful life may be shortened if it is used for liquids such a...

Страница 7: ...bottle which contains the phthalate pH standard solution Remove the protection bottle before measuring Reinstall the protection bottle after measurement 1 Removing the glass electrode protection bottl...

Страница 8: ...auto power off Note Auto power off is no longer cancelled once the unit is turned off Perform the auto power off canceling each time as necessary Calibration mode By performing the 3 point calibratio...

Страница 9: ...dicate that the calibration data has been stored in the unit memory Now the pH 4 calibration is complete 8 The unit automatically proceeds to the pH 7 calibration Wash the glass electrode with water d...

Страница 10: ...ature value will be displayed For details of the error codes refer to Troubleshooting Relation between pH value and temperature When performing calibration set the pH value according to the temperatur...

Страница 11: ...e factory 2 Inspection and calibration For an accurate pH measurement perform calibration using the pH standard solution If there is a deviation from the expected value adjust it before performing a p...

Страница 12: ...nsert the AC adapter plug into the AC adapter jack on the unit If an AC adapter other than the one provided by us is used choose one that meets the specifications described below Primary output Voltag...

Страница 13: ...th new battery Installing and replacing battery The power to the unit is turned off The auto power off is turned on Cancel the auto power off on the main unit Before measuring Error code pH display se...

Страница 14: ...with temperature Readings are abnormal The battery have run out Replace with new battery Installing and replacing battery The glass electrode of the sensor probe is dirty Wash the glass electrode Abou...

Страница 15: ...ower than 80 rh no condensing Battery Life About 20 hours continuous Materials Case ABS resin Electrode Glass Probe Epoxy resin Dimensions Main unit W 72 H 182 D 31 5mm Probe 12 x 135mm L cord length...

Страница 16: ......

Отзывы: