23
Temperature Measurement
The thermography (temperature measurement) function provides the real-
time temperature of the scene and display it on the left of your screen. The
thermography function is turned on by default.
Set Thermography Parameters
You can set thermography parameters to improve the accuracy of
temperature measurement.
Steps
1. Go to
Local Settings
→
Thermography Settings
.
2. Set the
Thermography Range
, and
Emissivity
, etc.
Thermography Range
Select the temperature measurement range. The device can detect the
temperature and switch thermography range automatically in
Auto
Switch
mode.
Emissivity
Refer to
Common Material Emissivity Reference
to set the
emissivity of your target.
Reflection Temperature
If any object (not the target) of high temperature is in the scene, and
the target emissivity is low, set the reflection temperature as the high
temperature to correct the thermography effect.
Distance
The distance between the target and the device. You can customize
the target distance or select the target distance as
Near
,
Middle
, or
Far
.
Environment Temperature
The average temperature of the environment.
Humidity
Set the relative humidity of current environment.