background image

2 MPD-300 

SATEL 

test

 – the detector operates like in the normal mode, but the alarms are signaled by the LED (the 

LED is lit for 2 seconds). 

To select between normal mode and energy saving mode, use the E-SAVE MODE pins (Fig. 1). 
The test mode is turned on for 20 minutes after inserting the batteries or opening the tamper 
contact. 
The detector monitors the signal path for correct operation. Failure of the signal path is indicated 
by the LED (2 flashes every 40 seconds). 
Every 15 minutes, the detector sends a transmission containing information on the status of the 
signal path, tamper contacts and battery. Periodic transmissions are used to monitor presence 
and operation of the detector. In the test mode, this transmission is indicated by the LED lighting 
for 80 milliseconds. 
 Fig. 1. View of the detector electronics board. 
1 -  CR123A battery. The detector checks the 

battery status. When the voltage is lower than 
2.6 V, the low-battery information is sent 
during each transmission. 

2 -  detector configuration pins: 

E-SAVE MODE

  -  operating mode selection: 

pins shorted – energy save mode; 
pins open – normal mode. 

PET MODE

 

-  pet immunity option: 

pins shorted – option enabled; 
pins open – option disabled. 

HIGH SENS.

 - 

sensitivity 

selection: 

pins shorted – high sensitivity (Fig. 2); 
pins open – normal sensitivity (Fig. 3). 

3 -  LED indicator. 
4  -  tamper contact activated by detector removal from the back tamper unit. 
5  -  tamper contact activated by cover removal. 
6 -  pyroelectric sensor. 
7  -  scale for positioning of pyroelectric sensor against the lens (Fig. 9). 
 

 

Содержание MPD-300

Страница 1: ...0 µA Maximum current consumption 20 mA Detectable speed 0 3 3 m s Environmental class according to EN50130 5 II Operating temperature range 10 C 55 C Maximum humidity 93 3 Recommended installation height 2 4 m Enclosure dimensions 63 x 96 x 49 mm Weight 108 g Hereby SATEL sp z o o declares that this detector is in compliance with the essential requirements and other relevant provisions of Directiv...

Страница 2: ... and operation of the detector In the test mode this transmission is indicated by the LED lighting for 80 milliseconds Fig 1 View of the detector electronics board 1 CR123A battery The detector checks the battery status When the voltage is lower than 2 6 V the low battery information is sent during each transmission 2 detector configuration pins E SAVE MODE operating mode selection pins shorted en...

Страница 3: ...ection Do not touch the pyroelectric sensor so as not to soil it 1 Open the enclosure Fig 4 2 Configure the detector by means of jumpers 3 Install the battery and register the detector in the MICRA alarm module see the manual for MICRA alarm module 4 Select the place of installation Check that the transmissions from the detector placed at that point reach the MICRA alarm module In order to send a ...

Страница 4: ...osure base to the back tamper unit Fig 8 8 Fasten the electronics board taking into account the height of detector installation Fig 9 9 Close and open the tamper contact that detects the cover removal to start the test mode and then close the detector enclosure 10 Check that movement within the coverage area will make the LED light up SATEL sp z o o ul Schuberta 79 80 172 Gdańsk POLAND tel 48 58 3...