background image

The VERSA-KWRL2 wireless keypad enables operation and programming of the VERSA, 
VERSA IP and VERSA Plus control panels with firmware version 1.09 (or newer). The device 
is designed for work within the ABAX 2 / ABAX two-way wireless system. This manual 
applies to the keypad with firmware version 3.00 (or newer), which is supported by: 

  ABAX 2: ACU-220 / ACU-280 controller, 

  ABAX: ACU-120 / ACU-270 controller (firmware version 5.04 or newer). 

The ABAX 2 / ABAX controller must be connected to the communication bus of the 
VERSA / VERSA IP / VERSA Plus alarm control panel. 

In the ACU-220 / ACU-280 controller, switch 9 must be set in OFF position, and switch 
10 must be set in ON position. 

In the ACU-120 / ACU-270 controller, switch 8 must be set in ON position. 

The keypad is not supported by the ARU-100 and ARU-200 radio signal repeaters. 

 

 

Fig. 1. VERSA-KWRL2 keypad. 

 

1.  Features 

  Display 2 x 16 characters with backlight. 

  LEDs indicating the state of partitions and system. 

  12 keys, bearing designations according to telephone standard and intended for entering 

data. 

  4 additional keys for menu navigation and arming/disarming. 

Содержание VERSA-KWRL2

Страница 1: ...VERSA KWRL2 Wireless keypad Firmware version 3 00 versa kwrl2_en 04 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel pl...

Страница 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Страница 3: ...roller must be connected to the communication bus of the VERSA VERSA IP VERSA Plus alarm control panel In the ACU 220 ACU 280 controller switch 9 must be set in OFF position and switch 10 must be set...

Страница 4: ...urs or an entry delay or an exit delay begins see description of the Wake up parameter section Settings stored in ABAX 2 ABAX controller p 6 When the keypad is in the wake up mode it works in much the...

Страница 5: ...ttery improperly Be particularly careful during installation and replacement of the batteries The manufacturer is not liable for the consequences of incorrect installation of the battery The used batt...

Страница 6: ...wall different for plaster wall etc When installed the device must withstand a pull off force of at least 50 N 10 Put the cover on the catches and snap the enclosure shut 11 Lock the cover using screw...

Страница 7: ...ypad data will be automatically written to the control panel 3 1 2 LCD keypad You can add wireless keypads in the service mode by means of the New device function 2 Hardware 1 Kpds exps 3 Wireless mod...

Страница 8: ...Kpds exps 3 Wireless dev 2 Config device wireless keypad name 4 1 1 Description of parameters and options Presence contr if this option is enabled the keypad presence is being monitored If there is no...

Страница 9: ...signal of zones Zone chime the keypad can audibly signal violation of selected zones If the zone is armed violation will not trigger the CHIME signal The wireless keypad signals the CHIME from zones n...

Страница 10: ...are fully armed if the option is disabled the LED goes off after just one of the partitions is armed in any mode Fig 4 DLOADX program keypad settings stored in the control panel Show code entering Cod...

Страница 11: ...ssages Partitions Part alarm msg if this option is enabled messages on partition alarms will be displayed they contain the name of partition Zones Zone alarm msg if this option is enabled messages on...

Страница 12: ...3 Proximity cards Arming Card hold down if you select this option the user will have to bring the card close to the keys and hold it still for about 3 seconds to arm the system Card read if you select...

Страница 13: ...reat each key pressing exactly in the same way When in the wake up mode the wireless keypad works much in the same way as the wired LCD keypad For how to use the keypad please refer to the control pan...

Страница 14: ...nt consumption BT2 battery card reader disabled 30 mA Maximum current consumption BT2 battery card reader enabled 40 mA Environmental class according to EN50130 5 II Operating temperature range 10 C 5...

Отзывы: