SATEL VERSA-KWRL2
9
be enabled in the control panel – refer to the control panel programming manual). The
signaling will be turned off after reviewing the trouble with the “7. System state”
user
function. The new troubles will not be signaled, if the “Grade 2”
option is enabled in the
control panel.
Auto-Arm delay countdown
[Autoarm signal.] – if this option is enabled, the keypad audibly
signals the auto-arm delay countdown.
Arm mode review
[Arm mode check.] – if this option is enabled, holding down the
key
for about 3 seconds will display information on the partition status. The users cannot check
the partition status using the
key, if the “Grade 2” option is enabled in the control
panel.
Date/Time format
– the way how date and time will be presented on the display.
LCD backlight
– the way how the display backlight will work, when the keypad is in the
wake-up mode:
not present
– disabled.
permanent 50%
– enabled: brightness 50%.
permanent 100%
– enabled: brightness 100%.
auto 0-50%
– enabled: brightness 50%.
auto 0-100%
– enabled: brightness 100%.
auto 50%-100%
– enabled: brightness 100%.
Keys backlight
– the way how the keys backlight will work, when the keypad is in the
wake-up mode:
not present
– disabled.
auto
– enabled.
permanent
– enabled.
Alarm messages
Partitions
[Part.alarm msg.] – if this option is enabled, messages on partition alarms will be
displayed (they contain the name of partition).
Zones
[Zone alarm msg.] – if this option is enabled, messages on alarms from zones will be
displayed (they contain the name of zone). The zone alarm messages have the priority.
The messages will not be displayed, if the “Grade 2” global option is enabled.
Alarms
PANIC alarm
– if this option is enabled, pressing the
key for approx. 3 seconds will
trigger the panic alarm.
silent
[Silent panic] – if this option is enabled, the panic alarm triggered from the keypad will
be a silent one, i.e. the keypad will not indicate it, there will be no audible signal, but the
alarm will be reported to the monitoring station. The silent panic alarm is useful when the
control panel is sending events to the monitoring station, but unauthorized persons should
not be aware of the alarm being triggered. The option is available, if the “PANIC alarm”
option is enabled.
FIRE alarm
– if this option is enabled, pressing the
key for approx. 3 seconds will
trigger the fire alarm.
AUX. alarm
[Medical alarm] – if this option is enabled, pressing the
key for approx. 3
seconds will trigger the auxiliary (medical) alarm.
Alarm 3 incorrect codes
[3 wrong codes] – if this option is enabled, entering invalid code
three times will trigger the alarm.
The auto-backlight parameters do not affect the wireless keypad performance.