2
RE-1K • RE-2K
SATEL
Terminals
SS
- output signaling the activation of the relay output (turning the relay on in the
pulse and monostable modes; switching the relay over in the bistable mode).
The indication is provided in the form of three short (0.16 second) pulses. OC
type output (shorted to common ground when active). You can connect e.g.
a siren to the SS output.
+12V
- power input (9...16 V DC).
COM
-
common
ground.
TMP
- NC type tamper output (opening the tamper switch opens the output). You can
connect the TMP output to the appropriately programmed output of the alarm
control panel.
C1, C2
- relay output common contact.
NC1, NC2
- relay output normally closed contact.
NO1, NO2
- relay output normally open contact.
Note: The RE-1K controller has no terminals of relay output 2.
3. Keyfobs
The controller supports the following SATEL 433 MHz keyfobs:
MPT-300
– 5-button keyfob,
T-4
– 4-button keyfob,
T-2
– 2-button keyfob,
T-1
– 1-button keyfob,
P-4
– 4-button keyfob,
P-2
– 2-button keyfob.
The controller is delivered with two T-2 keyfobs.
3.1 Keyfob battery replacement
The battery life depends on how the keyfob is used. The more frequently the buttons are
pressed, the faster the battery drains. When the controller indicates that the battery is running
low (LED; LV output), replace the battery as soon as possible.
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
4. Installation
Disconnect power before making any electrical connections.
Changes, modifications or repairs not authorized by the manufacturer shall void your rights
under the warranty.