OPAL Pro
Outdoor dual technology motion detector
Firmware version 2.00
opal_pro_en 03/21
SATEL sp. z o.o.
• ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
Страница 1: ...OPAL Pro Outdoor dual technology motion detector Firmware version 2 00 opal_pro_en 03 21 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...
Страница 2: ...hts under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes be...
Страница 3: ...unting 8 Angle bracket mounting 8 Ball bracket mounting 9 Connecting the additional tamper switch 11 5 Configuring the detector 11 Starting configuration mode 11 Signaling in the configuration mode 11...
Страница 4: ...le Remote configuration mode enable disable Supervision of motion detection system and supply voltage Tamper protection against cover removal and tearing enclosure from the wall Weatherproof enclosure...
Страница 5: ...vision features In the event of the voltage drop below 9 V 5 for more than 2 seconds or the motion detection system failure the detector will signal a trouble The trouble is indicated by the activatio...
Страница 6: ...abled If the detector is used in the INTEGRA INTEGRA Plus alarm system you can connect to the terminal the OC type control panel output programmed e g as Zone test status or BI switch Remote configura...
Страница 7: ...during sensors sensitivity setting MODE button used for the detector configuration see Configuring the detector PIR sensor dual element pyrosensor tamper switch activated by cover removal fixing screw...
Страница 8: ...ector sensitivity Fig 3 II Install the detector so that the expected movement of an intruder will be across the coverage pattern Fig 3 III Don t install the detector closer than 3 meters from the movi...
Страница 9: ...able in the enclosure base 4 Mount the enclosure base to the wall see Wall mounting to the angle bracket see Angle bracket mounting or to the ball bracket see Ball bracket mounting In Figure 6 possibl...
Страница 10: ...nti mask accordingly When the environment analysis is in progress the enclosure must be closed and the detector must not be covered by any undesirable objects Wall mounting 1 Run the cable through the...
Страница 11: ...mper switch Fig 8 II screw the tamper unit to the ball bracket Fig 8 IV 2 Run the cable through the opening in the handle of the bracket 3 Using wall plugs screw anchors and screws fasten the ball bra...
Страница 12: ...10 OPAL Pro SATEL...
Страница 13: ...reen LED starts to blink it means that you can configure the sensitivity of the microwave sensor Entering the configuration mode disables the anti mask feature The anti mask feature will be automatica...
Страница 14: ...gs for the configured sensor By pressing the next sensor or the previous sensor go to another sensor configuration Blinking of the proper LED will indicate which sensor is being configured see Signali...
Страница 15: ...ay of changing sensitivity are described in detail in the chapter Configuring the detector 1 Start the configuration mode 2 Choose the sensor to be tested 3 Check that moving in the coverage area will...
Страница 16: ...2 3 m s Alarm signaling period 2 s Warm up period 40 s Recommended installation height 2 4 m Security grade Grade 3 Standards complied with EN50131 1 EN 50131 2 4 EN50130 4 EN50130 5 IP code IP54 Envi...