6
Installer Manual
SATEL
INT-KWRL
– wireless LCD keypad with mechanical keys and built-in proximity card reader
(connection of the ACU-120 / ACU-270 controller required).
INT-KWRL2
– wireless LCD keypad with mechanical keys and built-in proximity card reader
(connection of the ACU-220 / ACU-280 / ACU-120 / ACU-270 controller required).
The recommended version of the keypad firmware (provides functionality consistent
with the requirements of EN 50131 for Grade 2):
−
INT-KLCD / INT-KLCDR – 1.08 (or later),
−
INT-KLCDK / INT-KLCDL / INT-KLCDS – 6.08 (or later),
−
INT-KSG – 1.02 (or later).
The keypads are available in a variety of color options for the enclosure, display and key
backlight. The color variant is indicated by the additional designation in the keypad name
(e.g. INT-KLCD-GR – green display and key backlight; INT-KLCD-BL – blue display and key
backlight).
For information on INT-KSG, INT-KWRL, INT-KWRL2, INT-TSG, INT-TSG2, INT-TSH,
INT-TSH2 and INT-TSI keypads, please refer to the manuals delivered with respective
keypads.
3.1 Features of keypads with mechanical keys
•
Display 2 x 16 characters with backlight.
•
LEDs indicating the status of the partitions and the system.
•
Backlit keys.
•
Built-in sounder.
•
2 programmable hardwired zones:
– support for NO and NC detectors,
– support for Single EOL and Double EOL configuration.
•
Tamper protection in 2 ways – cover removal and tearing enclosure from the wall.
•
RS-232 port (PIN-5 socket) for administration of the security alarm system by means of
a computer with the GUARDX program installed.
4. Expansion modules
The expansion modules allow you to not only increase the number of available zones and
outputs (wired and wireless), but also enhance the system with additional functionality.
Not all of the following modules meet the requirements of EN 50131 for Grade 2.
4.1 Modules to be connected to the keypad bus
CA-64 PTSA. Mimic board.
Enables visualization of the status of the alarm system partitions
and zones. The control panels support the mimic boards with electronics version 1.4 (or
later) and firmware version 4.0 (or later).
ETHM-1 Plus / ETHM-1. Ethernet communication module.
Enables reporting events as
well as operating and programming the control panel via the Ethernet network. The
recommended module version: 1.06 (or later).
INT-GSM. GPRS communication module.
Enables reporting events as well as operating
and programming the alarm control panel via the cellular data network (GPRS).