To set the address, use the DIP switches on the electronics board. The switches have
numbers assigned to them. The number for OFF position is 0. The numbers assigned to the
switches in ON position are presented in the table 1. The sum of these numbers is the
address set.
Switch (ON position)
1
2
3
4
5
Number
1
2
4
8
16
Table 1.
Fig. 3. Examples of code lock address setting.
2.2 Description of terminals
NO
- relay output
12V
- power input
DTA
- data (expander communication bus)
CLK
- clock (expander communication bus)
COM
- common ground
IN
- door status input (NC)
3. Configuring
The code lock settings you can configure using:
•
DLOADX program:
“Structure” window
“Hardware” tab
“Expansion modules”
branch
[code lock name]
,
•
LCD keypad:
“Service mode”
“Structure”
“Hardware”
“Expanders”
“Settings”
[code lock name]
.
3.1 Description of parameters and options
Names of parameters and options from the DLOADX program are used in this manual.
Shown in square brackets at the description of a parameter or option is the name presented
on the display of the LCD keypad.
Name
– individual name of the device (up to 16 characters).
Partition
– partition to which the code lock belongs (alarms will be triggered in this partition).
Lock features
[Lock function] – mode of operation of the relay output after the access is
granted:
Fixed ON time
[ON time] – the relay output will be turned on for the “Relay ON time”.
Fixed ON time – OFF if door open
[ON, open
off] – the relay output will be turned on
until the door is opened (door status input is disconnected from common ground),
however not longer than for the “Relay ON time”.