background image

INT-SK-GR SATEL 

 

5

operated by 

means of the partition keypad.

 This function is made available to any user 

selected in the „Users” option. The operation is effected by controlling the 

NO

 relay contacts 

(closed; open). The normal (basic) state of the relay contacts depends on how the „Relay 
type” option is set. Description of the function refers to a typical application. 

Lock feature 

(DLOADX) / 

Lock 

(DLOAD64)

 

ON if partition armed

 - selecting this option sets the bistable operating mode of the relay 

(i.e. it is active when the partition is armed and normal when the partition is disarmed). 

Note: 

When operating in this mode the relay will change its state automatically, if the 
partition is disarmed from the given keypad. When the partition is disarmed from 
another keypad, the state of the relay will change on entering the CODE and pressing 
the [*] key on the given partition keypad. 

Fixed ON time 

[ON time]

 

- this option sets the monostable operating mode of the relay. 

When the door opening function is called by the user ([CODE] [*]), the relay gets 

activated for the time period entered in the „

Relay ON time

”, and then returns to its 

normal state. 

Fixed ON time - OFF if door open

 [ON, open

Æ

off] - the relay is active until the door is 

opened (the IN input disconnected from common ground), but not longer than for the 
„relay ON time”. 

Fixed ON time - OFF if door closed

 [ON, close

Æ

off] - the relay is active during the time 

when the door is open (the IN input cut off from the common ground) and deactivates 
on closing the door (reconnection of the IN input to common ground), but not longer 
than for the „relay ON time”. 

Relay ON time

 – the time period during which the relay is active. Duration of the „relay ON 

time” can be from 

1

 to 

255

 seconds. 

Relay 

- this option defines the operating mode of the relay contacts: 

NO

 - the NO contacts are normally open, they close on activating the relay (during its 

active state), 

NC

 - the N

С

 contacts are normally closed, they open on activating the relay (during its 

active state).

 

Authorization

 

control

 

[Unauth. event] – opening the door without entering a password from 

the keypad (e.g. with the key) will generate an „Unauthorized door opening” event, it 
can also be signaled on the output type 93 (U

NAUTHORIZED ACCESS

). 

Alarm on unauth. access 

[Unauth. alarm]

 

– when the partition to which the module is 

assigned is armed, unauthorized opening of the door will trigger the alarm and can be 
additionally signaled on the output type 94 (A

LARM

 – U

NAUTHORIZED ACCESS

). 

Max. door open time

 - this option defines the time after expiry of which the module will 

report the „Long opened door” event to the control panel and activate the audible alarm. 
The duration can be set from 

0

 to 

255

 seconds. 

Dependent on door 1 

(or 

Dependent on door 2

)

 

- this function provides a list to choose the 

door which must be closed for the lock to operate. Monitoring of the door state is 
effected through the IN input in the partition keypad, code lock or CA-64 SR expander of 
proximity card readers, or through the zone type 57 (

TECHNICAL 

-

 

D

OOR OPEN

). Two 

dependent doors can be selected. The function allows to create a „sluice” type passage. 

Master users / Users

 - this function defines master users / users authorized to use the given 

keypad. 

Содержание INT-SK-GR

Страница 1: ...lled partition while blinking indicates that an alarm was triggered in the partition ARMED green color steady light indicates that the partition to which the keypad is assigned has been armed Blinking...

Страница 2: ...d COM common ground 12V power supply input CLK DTA expander bus 3 Installation and connection of the module The partition keypad is designed for indoor installation It may be mounted either directly t...

Страница 3: ...n be used for this purpose Details regarding the cable connections are described in the installer s manual for the alarm control panel 7 Connect the wires of the door state control sensor to the IN an...

Страница 4: ...ns Figure 4 DLOADX program window with partition keypad options Name the option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows Service m...

Страница 5: ...or reconnection of the IN input to common ground but not longer than for the relay ON time Relay ON time the time period during which the relay is active Duration of the relay ON time can be from 1 to...

Страница 6: ...acoustic alarm signaling in the given partition until the alarm is cleared Signaling entry delay acoustic signaling of the countdown of entry delay time Signaling exit delay acoustic signaling of the...

Страница 7: ...not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled 6 Technical data Nominal supply voltage 15 12V D...

Страница 8: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...

Отзывы: