INT-SK-GR SATEL
5
operated by
means of the partition keypad.
This function is made available to any user
selected in the „Users” option. The operation is effected by controlling the
NO
relay contacts
(closed; open). The normal (basic) state of the relay contacts depends on how the „Relay
type” option is set. Description of the function refers to a typical application.
Lock feature
(DLOADX) /
Lock
(DLOAD64)
ON if partition armed
- selecting this option sets the bistable operating mode of the relay
(i.e. it is active when the partition is armed and normal when the partition is disarmed).
Note:
When operating in this mode the relay will change its state automatically, if the
partition is disarmed from the given keypad. When the partition is disarmed from
another keypad, the state of the relay will change on entering the CODE and pressing
the [*] key on the given partition keypad.
Fixed ON time
[ON time]
- this option sets the monostable operating mode of the relay.
When the door opening function is called by the user ([CODE] [*]), the relay gets
activated for the time period entered in the „
Relay ON time
”, and then returns to its
normal state.
Fixed ON time - OFF if door open
[ON, open
Æ
off] - the relay is active until the door is
opened (the IN input disconnected from common ground), but not longer than for the
„relay ON time”.
Fixed ON time - OFF if door closed
[ON, close
Æ
off] - the relay is active during the time
when the door is open (the IN input cut off from the common ground) and deactivates
on closing the door (reconnection of the IN input to common ground), but not longer
than for the „relay ON time”.
Relay ON time
– the time period during which the relay is active. Duration of the „relay ON
time” can be from
1
to
255
seconds.
Relay
- this option defines the operating mode of the relay contacts:
NO
- the NO contacts are normally open, they close on activating the relay (during its
active state),
NC
- the N
С
contacts are normally closed, they open on activating the relay (during its
active state).
Authorization
control
[Unauth. event] – opening the door without entering a password from
the keypad (e.g. with the key) will generate an „Unauthorized door opening” event, it
can also be signaled on the output type 93 (U
NAUTHORIZED ACCESS
).
Alarm on unauth. access
[Unauth. alarm]
– when the partition to which the module is
assigned is armed, unauthorized opening of the door will trigger the alarm and can be
additionally signaled on the output type 94 (A
LARM
– U
NAUTHORIZED ACCESS
).
Max. door open time
- this option defines the time after expiry of which the module will
report the „Long opened door” event to the control panel and activate the audible alarm.
The duration can be set from
0
to
255
seconds.
Dependent on door 1
(or
Dependent on door 2
)
- this function provides a list to choose the
door which must be closed for the lock to operate. Monitoring of the door state is
effected through the IN input in the partition keypad, code lock or CA-64 SR expander of
proximity card readers, or through the zone type 57 (
TECHNICAL
-
D
OOR OPEN
). Two
dependent doors can be selected. The function allows to create a „sluice” type passage.
Master users / Users
- this function defines master users / users authorized to use the given
keypad.