Control “MONO”  output 

[MONO outs ctr.] –  if this option is enabled, the ““Mono” output 

operating” type of users can use the keypad to control outputs. 

Partition blocking 

[Part.blocking] – if the option is enabled, using the code by a user of the 

“Blocking  partition” or “Guard” type will block the armed partition (violating a zone 
belonging to the partition will trigger no alarm). The duration of blocking is to be defined for 
the partition or the user (the user of “Blocking partition” type). 

Guard round control

 [Guard control] – if this option is enabled, using the code by a user of 

the “Guard” type will be registered as the guard round. 

Changing access code

 

[Changing code] –  if this option is enabled, the user can change 

own code from the partition keypad. 

Exit delay clearing enable

 [Fin.exit time] – if the option is enabled, the user can terminate 

the partition exit delay countdown by pressing successively 

  and 

  (if the “Exit 

delay clearing” option is enabled for the partition). 

Alarm signal

 [Alarm (time)] – if this option is enabled, the keypad will audibly signal alarms 

throughout the “Global alarm time” (parameter programmed in the control panel). 

Alarm signal (until canceled)

 [Alarm (latch)] – if this option is enabled, the partition keypad 

will audibly signal alarms until they are cleared. 

Sign. entry delay

  [Entry time] –  if this option is enabled, the partition keypad will audibly 

signal the entry delay countdown. 

Sign. exit delay

 [Exit time] – if this option is enabled, the partition keypad will audibly signal 

the exit delay countdown. 

Auto-Arm delay countdown

 [Auto-arm delay] – if this option is enabled, the partition keypad 

will audibly signal the auto-arm delay countdown. 

Acc. code sign. (hardware)

 [Code entered] – if this option is enabled, the partition keypad 

will confirm with a single beep that the code has been entered. The signaling is useful 
when there is a delay between entering the code and the sounds emitted after verification 
of the code by the control panel. 

CHIME

  [Chime zones] –  if this  option is enabled, the partition keypad will audibly signal 

violation of zones with “Chime in module” option enabled, belonging to the partition 
operated by means of the keypad. 

No auto-reset after 3 tamp.

 [No autorst.3t.] – if this option is enabled, the feature reducing 

the number of tamper alarms from the module to three is disabled (the feature prevents 
multiple logging of the same events and applies to successive uncleared alarms). 

Backlight

 – keys backlight operation mode: 

No

 – always off. 

Auto

 – on for about 40 seconds after pressing any key. Additionally, it can be turned on if 

a specific event occurs (see the “Auto-backlight”

 

parameter). 

Permanent

 – always on. 

Auto-backlight

  –  if the keys  backlight comes on automatically, you can additionally define 

whether and what event will turn the backlight on: 

No

 – the keys backlight will not be additionally turned on. 

Zone violation

 – the keys backlight will additionally go on if a selected zone is violated. 

Entry delay, part.

  –  the keys backlight will  additionally go on if entry delay countdown 

starts in the selected partition. 

Unlock door if fire

  [Doors on fire] –  you can define whether and when the fire alarm will 

unlock the door controlled by the partition keypad (i.e. will activate the relay output): 

No

 [no open] – the door will not be unlocked in the event of fire alarm. 

Содержание INT-S Series

Страница 1: ...INT S Partition keypad Firmware version 2 02 int s_en 07 20 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...rights under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the change...

Страница 3: ...ndicators 8 4 2 Sound signaling 8 4 2 1 Beeps generated when operating 8 4 2 2 Signaling events 8 4 3 Code 9 4 4 Available functions 9 4 4 1 Code 9 4 4 2 Code 10 4 4 3 Quick arming 10 4 4 4 Triggering...

Страница 4: ...INT S partition keypad with closed and open flap cover 1 Features Arming disarming and alarm clearing in partition Capability of triggering alarm from the keypad Single door control relay output for c...

Страница 5: ...d pair type of cable remember that CLK clock and DTA data signals must not be sent through one twisted pair cable The wires must be run in one cable 8 If the partition keypad is to control an electric...

Страница 6: ...2 Description of terminals NO relay output 12V power input DTA data expander communication bus CLK clock expander communication bus COM common ground IN door status input NC 3 Configuring The keypad s...

Страница 7: ...cess the user must disarm the partition Fixed ON time ON time the relay output will be turned on for the Relay ON time Fixed ON time OFF if door open ON open off the relay output will be turned on unt...

Страница 8: ...is option is enabled entering the code and pressing will not disarm the partition to disarm the partition the user must enter the code and press Access if armed Code in arm if the option is enabled th...

Страница 9: ...Auto arm delay if this option is enabled the partition keypad will audibly signal the auto arm delay countdown Acc code sign hardware Code entered if this option is enabled the partition keypad will c...

Страница 10: ...icate that there is no communication with the control panel 4 2 Sound signaling 4 2 1 Beeps generated when operating The installer can disable the sound signaling or replace it with flashing of the ke...

Страница 11: ...ontrol panel service code 12345 object 1 master user administrator code 1111 The factory default codes should be changed before you start using your alarm system Do not make your code available to oth...

Страница 12: ...art the partition arming procedure if the exit delay is 0 the partition will be armed instantly 4 4 4 Triggering the alarm from keypad The installer can permit triggering alarms from the keypad To tri...

Страница 13: ...cannot be initiated if there are violated zones in the partition or there is a trouble in the system the partition will not be armed if at the moment of completion of exit delay countdown there is a...

Отзывы: