SATEL INT-KNX 

Group address

 

– group address, whose presence in the received telegram will enable 

control of the given zone. 

Zone

 

– the number of zone to be controlled by telegrams sent by the bus devices. 

Receiving a telegram with the "On" command by the INT KNX module will violate the 
zone (if it has already been violated, its status will not change), and receiving 
a telegram with the "Off" command will restore the zone (if it has not been violated, 
its status will not change). 

Negation

 

– when this option is active, the logic of zone operation will be reversed (the 

zone will be violated on receiving a telegram with the "Off" command by the INT KNX 
module, and the zone restore will occur on receiving a telegram with the "On" 
command. 

Note:

 The data are not read from / written to the module when using the 

 and 

 

buttons in the main menu of D

LOAD

X program. 

5. Specifications 

Supply voltage ................................................................................................... 12 V DC ±15% 
Standby current consumption ..........................................................................................35 mA 
Maximum current consumption........................................................................................35 mA 
Environmental class................................................................................................................. II 
Operating temperature range.............................................................................-10 °C...+55 °C 
Maximum humidity.......................................................................................................... 93±3% 
Electronics board dimensions ................................................................................. 57 x 80 mm 
Weight............................................................................................................................... 140 g 
 
 
 
 
 
 
 
 
 
 
 
 

Note:

 If the telegrams sent by the INT-KNX module are blocked by the line/area couplers, 

use the so-called "dummy application" available from the manufacturer of BCU or 
another company (e.g. GIRA large dummy application 900201). This will allow group 
addresses to be added to the project. Do not load the application onto the device. 

 
 

Содержание INT-KNX

Страница 1: ...support for On and Off commands RS 232 port for connecting the module to the BCU Dedicated adapter interface and cable for connecting the module to the BCU 2 Installation Disconnect power before maki...

Страница 2: ...battery presence by periodically lowering the voltage make sure that the battery is present for correct operation of the INT KNX module 6 Install and connect the BCU to the KNX bus in accordance with...

Страница 3: ...ion with the control panel 3 male socket DB 9 RS 232 port to connect the module to the Bus Coupling Unit BCU using the cable included in the delivery set Description of terminals TMP tamper circuit in...

Страница 4: ...outputs 24 1 address is allocated for each group of 8 outputs on the expander bus The module can occupy up to 8 addresses on the expander bus The control panel assigns consecutive addresses to the mo...

Страница 5: ...e module with the DLOADX program use the Read button to read data from the module see Fig 5 The program can suggest reading the data itself when you click on the module name in the Structure window Ha...

Страница 6: ...sent after activating deactivating the output Telegram type depending on the selected telegram type 0 Toggle on activating the output a telegram with On command is sent and on deactivating the output...

Страница 7: ...the Off command by the INT KNX module and the zone restore will occur on receiving a telegram with the On command Note The data are not read from written to the module when using the and buttons in t...

Страница 8: ...The declaration of conformity may be consulted at www satel eu ce SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel pl...

Отзывы: