SATEL INT-KNX 

4.  Programming the module 

The module can be programmed by means of: 

 LCD keypad: S

ERVICE MODE

 

X

S

TRUCTURE

 

X

H

ARDWARE

 

X

E

XPANDERS

 

X

S

ETTINGS

 

X

[module name]

  computer running D

LOAD

X program:

 

"Structure" window 

Æ

"Hardware" tab 

Æ

"Expansion 

modules" branch 

Æ

[module name]

Note:

  Some parameters can only be programmed with the D

LOAD

X program. 

4.1  Parameters and options 

Some of the parameters and options are stored in the control panel memory, and some of 
them in the module memory. Prior to programming the module with the D

LOAD

X program, use 

the "Read" button to read data from the module (see Fig. 5). The program can suggest 
reading the data itself when you click on the module name in the "Structure" window, 
"Hardware" tab. After programming, use the "Write" button to save the data to the module 
(see Fig. 5). The "Read" button is not intended to read the data from the control panel and 
the "Write" button – to write the data to the control panel. 
 

 

Fig. 5. Programming the INT-KNX module parameters and options in the D

LOAD

X program. 

 
You can restore the factory settings to the parameters and options stored in the module 
memory by using the "Reset" button in the D

LOAD

X program or the F

ACTORY SETS

 function in 

the keypad. 

Содержание INT-KNX

Страница 1: ...support for On and Off commands RS 232 port for connecting the module to the BCU Dedicated adapter interface and cable for connecting the module to the BCU 2 Installation Disconnect power before maki...

Страница 2: ...battery presence by periodically lowering the voltage make sure that the battery is present for correct operation of the INT KNX module 6 Install and connect the BCU to the KNX bus in accordance with...

Страница 3: ...ion with the control panel 3 male socket DB 9 RS 232 port to connect the module to the Bus Coupling Unit BCU using the cable included in the delivery set Description of terminals TMP tamper circuit in...

Страница 4: ...outputs 24 1 address is allocated for each group of 8 outputs on the expander bus The module can occupy up to 8 addresses on the expander bus The control panel assigns consecutive addresses to the mo...

Страница 5: ...e module with the DLOADX program use the Read button to read data from the module see Fig 5 The program can suggest reading the data itself when you click on the module name in the Structure window Ha...

Страница 6: ...sent after activating deactivating the output Telegram type depending on the selected telegram type 0 Toggle on activating the output a telegram with On command is sent and on deactivating the output...

Страница 7: ...the Off command by the INT KNX module and the zone restore will occur on receiving a telegram with the On command Note The data are not read from written to the module when using the and buttons in t...

Страница 8: ...The declaration of conformity may be consulted at www satel eu ce SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel pl...

Отзывы: