background image

SATEL GPRS-T4 

19 

 

 

Fig. 12. “CLIP / SMS messaging” tab. 

 

Restore 

– content of the SMS message that will be sent on the input restore. The message 

may consist of up to 24 characters. It may not contain any diacritical characters. If the field 
is left blank, the message will not be sent. 

Add input voltage value to message 

– if this option is selected, information on the current 

voltage value at the input will be added to the SMS message about the analog input 
status. 

For the analog inputs, the messaging parameters are to be defined separately for each 
of the defined thresholds. 

4.3.6  “Reporting” tab 

Indicate in the table in which situations the event code is to be sent to the monitoring station. 

S1 

– select this field if the event code is to be sent to the monitoring station 1. 

S2 

– select this field if the event code is to be sent to the monitoring station 2. 

Violation/pass Code / Restore Code 

– the event code that will be sent to the monitoring 

station when the input status changes. 4 digits are to be programmed in the following form: 
Q-XYZ, where: 
– 

Q

 – digit 1 or 3 (1 – new event/disarming, 3 – new restore/arming), 

– 

XYZ

 – 3-digit event code. 

You can also make use of the code editor. To open the code editor, click on the 

 button, 

available in the "EVENT" filed. 

Violation/pass Partition / Restore Partition

 – partition number which will be sent in 

the event code. You can enter numbers and letters from A to F. 

If events are to be sent in the form of two characters (partition number only), you 
should not use the code editor. 

Содержание GPRS-T4

Страница 1: ...GPRS SMS Reporting Module GPRS T4 Program version 3 01 gprs t4_en 10 13 SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel eu...

Страница 2: ...iff plan providing for at least 10 MB monthly data transfer SATEL s goal is to continually improve the quality of its products which may result in alterations of their technical specifications and fir...

Страница 3: ...sent in the form of GPRS transmission or SMS messages Using the GPRS technology makes it possible to send the codes to the STAM 2 monitoring station or SMET 256 converter The codes in SMS format can b...

Страница 4: ...nsmissions after identification of the calling party s telephone number CLIP service after receiving command from the GPRS SOFT program Option to check the status of available resources and account va...

Страница 5: ...king when GPRS transmission is going on LED B is blinking when SMS message is being sent or the module is calling CLIP test transmission the other LEDs indicate the level of signal received by the GSM...

Страница 6: ...Be careful not to damage the socket 2 Connect the devices whose operation is to be monitored by the module to the input terminals as required 3 Connect the wire of transformer secondary winding from w...

Страница 7: ...SATEL GPRS T4 5 Fig 4 Example of connecting power supply and testing AC voltage presence in GPRS T4 module 1 transformer 2 power supply unit 3 GPRS T4 module Fig 5 Installing the SIM card...

Страница 8: ...th factory default settings can only be programmed locally Provision is also made for programming some parameters of the module by means of SMS messages 4 1 Local programming through RS 232 TTL port T...

Страница 9: ...in the window that will open enter the number of TCP port selected for communication with the module The number will have to be included in the body of SMS message which will be sent to the module GS...

Страница 10: ...en a window indicating the server status The button color indicates the current communication status green computer COM port enabled server active yellow data transfer in progress gray computer COM po...

Страница 11: ...on between the program and the module is only possible when the identifier entered in this field is consistent with that stored in the module No identifier is preprogrammed in the module with factory...

Страница 12: ...S SOFT program has been entered as a name If all addresses are given in the IP address form 4 decimal numbers separated by dots programming the DNS server address is not required Other USSD codes forw...

Страница 13: ...ll be effected The port number must be the same as that programmed in the monitoring station Station key enter in this field a string of 1 to 12 alphanumeric characters digits letters and special char...

Страница 14: ...ns may be sent periodically at defined time intervals and also can be generated after identification of the telephone number of the calling party CLIP service or after receiving a command from the GPR...

Страница 15: ...enote new restore arming click on the field twice to select deselect it Part enter in this field the partition number which will be included in the event message sent to the monitoring station Zone n...

Страница 16: ...he CLIP service In order to acknowledge receiving the CLIP test transmission reject the call coming from the module Retries number if the Acknowledgement field is selected the test transmission with t...

Страница 17: ...evice status for the numbers in the list they will be sent by the module immediately for the numbers not in the list they can be sent by the module every 10 minutes at the most Control SMS messages ca...

Страница 18: ...em with logging into the GSM network can be caused by missing SIM card entering a wrong PIN code missing or damaged antenna unavailable GSM network out of range telephone damage Additional information...

Страница 19: ...shold the upper voltage threshold for analog input If the voltage rises above the defined value plus tolerance the module will register input violation Entering value 0 means that the voltage threshol...

Страница 20: ...the functions of block unblock the inputs may contain up to 24 characters 4 3 5 CLIP SMS messaging tab Notification can be effected by means of SMS messages or by using the CLIP service the module doe...

Страница 21: ...is to be sent to the monitoring station S1 select this field if the event code is to be sent to the monitoring station 1 S2 select this field if the event code is to be sent to the monitoring station...

Страница 22: ...eld is also the button which enables opening of the code editor For the analog inputs the reporting related parameters are to be determined separately for each of the defined thresholds 4 3 7 Tel numb...

Страница 23: ...update process Server address in SMS if this option is enabled you can enter the address of server to which the module is to connect and the port number in the content of SMS initiating the connection...

Страница 24: ...ne number T3 DEL4 to delete the phone number T4 3 Delete all phone numbers from the Telephone numbers for messaging and test transmissions list sending DELALL 4 Reset the number of transmissions sent...

Страница 25: ...S field enter the GSM telephone number through which the monitoring station receives SMS messages Tel number SMS field 3 Define the SMS message format in which the received event codes will be sent to...

Страница 26: ...containing the control command to initiate the process of module firmware update SMS initiating update Firmware update tab to the module telephone number The module will connect to the firmware updat...

Страница 27: ...S format Event Test transmission Control tab CLIP Reaction to CLIP only when number is on list of tel for messaging the option is enabled Control SMS control only from list of tel numbers for messagin...

Страница 28: ...26 GPRS T4 SATEL OC outputs rating 50 mA 12 V DC Environmental class II Working temperature range 10 55 C Electronics board dimensions 80 x 57 mm Weight 184 g...

Отзывы: