Monitoring station settings
Server address
– network address of the monitoring station.
Port
– enter in this field the number of TCP port through which communication with the
monitoring station will be effected. You can enter any value from 1 to 65535. By default:
12345.
Encryption key
– enter in this field a sequence of 1 to 12 alphanumeric characters (digits,
letters and special characters) to define the key for coding of the data to be sent to the
monitoring station.
System identifier
– enter in this field a sequence of 4 characters for identification of the
device. You can enter digits from 0 to 9 and letters from A to F. Using the digit 0 is not
recommended. Factory default: 0000 (this string is equivalent to the lack of identifier).
Together with the identifier, the codes of module generated events will be sent (inputs
monitoring, troubles, etc.).
SIA prefix
– select this box to activate the field for entering 2 characters which will
precede the “System identifier” in case of the SIA format. Thus you can obtain an
identifier consisting of 6 characters. 2 hexadecimal characters (digits or letters from A to
F) should be programmed. If you enter 00, no prefix will be added. Using the digit 0 in
the prefix is not recommended. The option is available if the SIA format is selected.
ETHM
key
– enter in this field a sequence of 1 to 5 alphanumeric characters for
identification of the Ethernet module.
Note: The data entered in the fields “Port”, “Encryption key”, “System identifier”
and “ETHM key” must be consistent with the corresponding settings defined in the
monitoring station.
Telephone line
Tel. number
– enter in this field the telephone number defined in the control panel for
a given monitoring station. Based on the telephone number, the module will determine,
whether to receive the event and to which monitoring station send it. If the field is blank