be used provided that the addressable module will still be supplied from the POW output
(such a connection is shown in Fig. 5).
In case of full configuration (48 expander zones used), when connecting the detectors with
DY 8x0,5 cable, the corresponding number of wires connected in parallel is to be provided for
the common ground of signal and the common ground of addressable modules supply (see
Table 4).
Distance Number
of
wires
up to 200m
1
up to 400m
2
up to 600m
3
Table 4.
Fig. 5. Connecting of addressable detectors to internal expander bus.
Fig. 6. Example of connecting the addressable detector without tamper control.
6. Installation
The addressable zones expander may be installed in any housing designed for control panel
(with transformer and place for battery). Begin installation of the housing with placement of
distance pins inside.
DETECTOR
INT
COM
POW
CA-64 ADR
EXPANDER
DETECTOR
DETECTOR
DETECTOR
signal and module supply common ground
detector supply common ground
+12V
COM
POWER
SUPPLY
CA-64 ADR MOD
adressable module
CA-64 ADR
detector
white
black
blue
red
detector supply common ground
signal and module supply common ground