SATEL
CA-6
KLED
2
−
ON with a short extinguishment every 2 seconds – detector tamper
(2EOL zone type),
−
flashing 2 every 2 seconds – tamper memory (detector was tampered
with - 2EOL zone type),
−
blinking slowly – zone bypassed (indicated only with the partition
disarmed).
Some of the control panel states are additionally indicated by the following LED
combinations:
•
[
POWER
] and
[
PHONE
] LEDs are blinking alternately - the control panel is in
the service mode;
•
[
POWER
],
[
PHONE
] and
[
TROUBLE
] LEDs are blinking simultaneously - the
control panel signals entering into the user functions menu;
•
[
POWER
],
[
PHONE
],
[
TROUBLE
] and
[
ALARM
] (both) LEDs are ON - the
control panel performs the alarm memory display function;
•
[
TROUBLE
] LED is blinking,
[
POWER
] and
[
PHONE
] LEDs are ON - the
control panel performs the trouble memory display function.
For further information regarding the installation and operation of the keypad please
refer to the I
NSTALLER MANUAL
and U
SER MANUAL
of the CA-6 alarm control panel.
Technical data
Nominal supply voltage (±15%).......................................................................... 12V DC
Average current consumption.................................................................................15mA
Operating temperature range ................................................................... -10°C…+55°C
Housing dimensions (width x height x thickness).................................... 144x80x27mm
The latest EC declaration of conformity and product approval certificates
are available for downloading on the
www.satel.pl
website
SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gda
ń
sk
POLAND
tel. + 48 58 320 94 00